1. <noframes id="S_RI8G">
      <noframes id="S_RI8G"><kbd></kbd>
          1. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

            Submersible electromagnetic flowmeter

            1潛(qian)水式(shi)電磁流量計01.png
            1潛水式(shi)電磁(ci)流(liu)量(liang)計(ji)02.png
            1潛(qian)水(shui)式電(dian)磁流量計03.png
            • 1潛水式電磁流(liu)量(liang)計(ji)01.png
            • 1潛水式(shi)電(dian)磁流量(liang)計02.png
            • 1潛(qian)水式(shi)電(dian)磁(ci)流(liu)量(liang)計(ji)03.png
            Submersible electromagnetic flowmeter by the diving electromagnetic flow sensor and diving electroma…

            Description:

            Products overview:
            ZW - LDE seriesSubmersible electromagnetic flowmeterIs advanced technology development, the development of the intelligent flowmeter, and the old analog or non intelligent electromagnetic flowmeter has a very big difference, especially in the measurement accuracy, reliability, stability, use function and service life, etc.Submersible electromagnetic is high precision, high reliability and long service life of flow meter, so in the design of product structure, material selection, process, production assembly and the factory testing of every link in the process of we are all very detailed standards, we also design a set of ideal home is current, applied to the production equipment of electromagnetic flowmeter and traffic flow calibration device, thus both in software and hardware can effectively guarantee high quality products for a long time.

            Second, the working principle:
            ZW - LDE seriesSubmersible electromagnetic flowmeter measurement principle is based on Faraday's law of electromagnetic induction electric liquid for cutting lines of magnetic force in magnetic field movement, the potential is induced in the conductor, the induced potential E as follows:
            E = KBVD;Type: K -- -- -- -- -- instrument constants;
            B -- -- -- -- -- magnetic induction intensity;
            V -- -- -- -- -- measurement of average flow velocity in the piping section;
            D -- -- -- -- -- measuring inner diameter of the pipe cross section;
            Measuring flow, the electrical conductivity of liquid with velocity V.
            Through the perpendicular to the flow direction of magnetic field, the flow of the liquid conductivity sense if a voltage is proportional to the average flow velocity, the induced voltage signal by two or more direct contact with the liquid electrode detection, and through the cable to the converter by intelligent processing, then the LCD display or converted into 4 ~ 20 ma 01 KHZ and standard signal output.

            Applications:
            ZW - LDE seriesSubmersible electromagnetic flowmeter is mainly used to measure volume flow of conducting liquid and slurry in the closed pipeline.Such as water, sewage, slurry, pulp, all kinds of acid, alkali, salt solution slurry, food and so on, the electromagnetic flowmeter is widely used in petrochemical, steel, metallurgy, water supply and drainage, irrigation, water treatment, environmental protection sewage total amount control, paper making, medicine, food and other industrial and agricultural sector of the production process flow measurement and control;Apply to the amount of conductive liquid measurement.

            Four, the main features:
            1, the amount of full digital processing, strong anti-interference ability, reliable measurement, high accuracy, the flow measurement range of up to 150:1;
            2, low EMI switching power supply, it is suitable for the power supply voltage variation range is big, EMI resistance performance is good;
            3, USES the 16-bit embedded microcontroller processor, a fast calculation speed, high precision, programmable frequency low-frequency rectangular wave excitation, improve the stability of the flow measurement, low power consumption.
            4, the SMD components and surface mount technology (SMT), circuit of high reliability;
            Have no moving parts, 5, and the pipe unimpeded flow components, almost no additional pressure loss in the measurement;
            6, in the field can be on-line modification range according to user's actual needs;
            7, measurement results and the velocity distribution, the fluid pressure, temperature, density, viscosity and other physical parameters has nothing to do;
            8, high-definition backlit LCD display, full Chinese menu operation, easy to use, simple operation, easy to understand;
            9, with RS485 and RS232, Hart and Modbus digital communication signal output.(optional).
            10, with functions of self-check and since the argument;
            11, total hours recording function, total hours for the unit to record the flow rate, is suitable for the time-sharing measurement system (optional);
            12, inside has three integrator can reverse the cumulative amount respectively show positive cumulative integrating quantity and difference, it has not always, can record 16 times time when power supply drop.(optional).
            13, infrared carrying manipulator, 115 KHZ communication rate, long distance non-contact operation converter all function (optional).
            Five, the technical parameters:
            1, precision instrument: pipeline magnitude 0.5, 1.0;Plug in 2.5 on the Richter scale;
            2, measuring medium: conductivity is greater than 5 mu S/cm of various liquid and liquid-solid two phase flow;
            3, velocity range: 0.2 ~ 8 m/s;
            4, work pressure: 1.6 MPa;
            5, environmental temperature: - 40 ℃ ~ + 50 ℃;
            6, medium temperature: ptfe lining 180 ℃ or less;Rubber lining 65 ℃ or less;
            7, explosion-proof marks: Exmibd Ⅱ BT4;
            8 and outside magnetic interference: 400 a/m or less;
            9, shell protection: integration type: IP65;
            10, points out: sensor IP68 (5 meters underwater, rubber lining only);Converter IP65;
            11, the output signal: 4 ~ 20 ma DC, 0 ~ 750 Ω load resistance;
            12, communication output: RS485 or CAN bus;
            13, electrical connections: M20 x 1.5 internal thread, phi 10 cable hole;
            14, power supply voltage: 90 ~ 220 v AC, 24 V.D C + / - 10%;
            15, power consumption: 10 or less va.
            Six, the structure form:
            1, the sensor:
            Sensor is mainly composed of measuring tube and electrode, excitation coils, iron core, magnetic yoke and shell. 
            A, measuring catheter: by stainless steel tube, the lining and the connecting flange, as the carrier of measured liquid measurement working conditions on site. 
            B, measuring electrode: installed in the measuring tube inside wall, and the axial direction perpendicular to a pair of electrodes to measure liquid signal generation. 
            : c, excitation coil in a magnetic field measurement of intraductal two excitation coil. 
            D, iron core and magnetic yoke: the excitation coil of the magnetic field generated import liquid, and the magnetic circuit. 
            E, shell: instrument packaging. 
            2, converter that is smart the secondary table, it will flow signal amplification processing, single chip microcomputer after the operation, can display flow, total amount, and can output pulse and analog current signal, used in the measurement or control of fluid flow.
            3, product assembly form: it into a shape and size in two forms. 
            A, a shape: mounted sensors and switches. 
            B, size: separation installation sensor and converter, through the connecting cable form flow metering system. 
            C, in order to adapt to the measurement demands of the different medium, the lining of sensor and electrode materials can have many choices.

            Seven, according to excitation methods of classification:
            To produce a uniform constant magnetic field, it needs to choose a suitable way of excitation.Such as divided according to the field current mode, have a dc field, ac (or other frequency) power frequency excitation, low-frequency rectangular wave excitation and dual-band rectangular wave excitation.
            1, the dc excitation
            Dc excitation method with direct current (dc) or use a magnet to produce a uniform magnetic field is constant.The dc excitation transmitter is affected by the ac electromagnetic interference is very small, so you can ignore the influence of the liquid in the self inductance.But using dc magnetic field is easy to make by measuring the electrolyte fluid of the pipe is polarized, the electrolyte by electrolysis in the electric field, produce positive and negative ions, in under the action of electric field force, ran to the anode, anion cation ran to the cathode, which will result in positive and negative electrodes were surrounded by ions of opposite polarity, seriously affect the normal work of the instrument.So, dc excitation only commonly used for measuring the liquid electrolyte, such as the liquid metal flow of mercury (room temperature and high temperature of liquid steel, lithium, potassium), etc.
            2, ac excitation
            Industrial use of electromagnetic flowmeter, most used (50 hz) power supply power frequency ac excitation method to produce alternating magnetic field, to avoid the dc excitation on the surface of the electrode polarization interference.But the use of ac excitation will bring a series of electromagnetic interference problem, such as orthogonal interference, in-phase interference, zero drift, etc.).Ac excitation is now replaced by low frequency square wave excitation.
            3, low frequency square wave excitation
            Low frequency square wave excitation waveform has two values (positive - negative) and three values (positive - zero - negative - zero) two kinds, the frequency of power frequency usually 1/2 ~ 1/32.Low frequency square wave excitation can avoid orthogonal electromagnetic interference of ac magnetic field, power frequency interference caused by distributed capacitance, inhibition of ac magnetic field within the tube wall and fluid caused by eddy current, dc excitation polarization phenomenon.

            Eight, the straight pipe installation requirements:
            Flowmeter sensor of straight pipe upstream and downstream of the installation points has certain requirements, otherwise it will affect the accuracy of measurement.
            1, if the sensor installation point upstream of reducer, sensors upstream should be not less than 15 d straight pipe sections, such as the downstream straight pipe section should be not less than 5 d.
            2, if the sensor is installed upstream of point have divergent tube, sensor should not be less than 18 d upstream straight pipe sections, such as the downstream straight pipe section should be not less than 5 d.
            3, if the sensor installed upstream of point under the 90 ° elbow or sub, sensors upstream should be not less than 20 d straight pipe sections, such as the downstream straight pipe section should be not less than 5 d.
            Upstream of four, if the sensor installed on the same plane has two 90 ° elbow, sensor should not be less than 25 d upstream straight pipe sections, such as the downstream straight pipe section should be not less than 5 d.
            Upstream of 5, if the sensor installed in different plane has two 90 ° elbow, sensors upstream should be not less than 40 d straight pipe sections, such as the downstream straight pipe section should be not less than 5 d.
            6, flow control valve or pressure regulating valve installed on the downstream side of the sensor 5 d as far as possible, if must be installed in the upstream of the sensor, the sensor should not be less than 50 d upstream straight pipe sections, such as the downstream straight pipe section should be not less than 5 d.
            Pay special attention to
            1, sensors installed upstream of point relatively close if equipped with valve, switch valve and affect the service life of the sensor is great, very easy to cause * sexual damage to the sensor.
            2, sensors to avoid the overhead of very long pipe installed on the sensor, so that over time, as the drop sensor is very easy to cause between the sensor and the flange seal leakage, if necessary when installation, must be set separately in the upstream and downstream of sensor 2 d pipe clamp device.
            Nine, installation considerations:
            1, the sensor should be installed vertically, and fluid flows from bottom to top, in order to meet the solid and liquid two is in a state of mixed.The reason is that if there is solid in the medium (sand, gravel particles, etc.) are prone to precipitation.Have fish and weeds in another line of fish swimming in the pipeline, will cause the flowmeter output swing;Hang back and forth near the electrode weeds can also cause the output of the meter is not stable.Set at the entrance of upstream flow meter metal screen blocking fish and weeds into the measuring tube.
            2, to prevent the negative pressure pipe set improper operation will cause negative pressure sensor inside.When closed, downstream of the valve in the flow meter at the same time, if the temperature is higher than the temperature of the fluid.Contraction after cooling, the pipe pressure is in danger of forming negative pressure.The negative pressure caused by the lining and metal vessel, cause leakage electrode.
            3, near the flowmeter and negative pressure to prevent valve, open the valve on atmospheric pressure, in order to prevent to produce negative pressure in the sensor.Flowmeter downstream by a vertical line, if use flow upstream of the valve to close or adjust the flow sensor, the sensor will form a negative pressure measuring tube.In order to prevent negative pressure, need to add back pressure or use downstream to adjust and close the flow valve.
            4, proper maintenance space, large diameter flowmeter are often installed in instrument well, for pipe installation, wiring, inspection and maintenance convenience, need to have the appropriate space.For observation, connection and maintenance convenience, instrument installation should have a certain height from ground, in order to facilitate cleaning, installation.

            Ten, the main technical data:

            1, the whole machine and the technology of sensor data:

            Execution standard

            JB/T 9248—1999

            Nominal diameter

            15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000

            High velocity

            15m/s

            precision

            DNl5~DN600

            Show the value of the: plus or minus 0.3% (velocity of 1 m/s or higher);Plus or minus 3 mm/s < 1 m/s (velocity)

            DN700—DN3000

            Plus or minus 0.5% of the value (velocity of 0.8 m/S or higher);Plus or minus 4 mm/s < 0.8 m/s (velocity)

            Fluid conductivity

            ≥5uS/cm

            Nominal pressure

            4.0MPa

            1.6MPa

            1.0MPa

            0.6MPa

            6.3、10MPa

            DNl5~DN150

            DNl5~DN600

            DN200~DN1000

            DN700~DN3000

            Special orders

            The environment temperature

            The sensor

            - 25 ℃ - 10 to 60 ℃

            Converter and a body

            - 10 ℃ - 10 to 60 ℃

            The lining material

            Ptfe, chloroprene rubber, polyurethane, fep (F46), and network PFA

            High fluid temperature

            - size

            70 ℃

            The separation type

            Poly (chloroprene rubber lining

            80 ℃;120 ℃ (when ordering specify)

            Polyurethane lining

            80 ℃

            Ptfe lining

            100 ℃;150 ℃ (when ordering specify)

            Fep (F46)

            And network PFA

            Signal electrode and the grounding electrode materials

            Stainless steel 0 crl8nil2m02ti B, C, hartz hartz alloy alloy, titanium, tantalum, platinum/iridium alloy, stainless steel coated with tungsten carbide

            Electrode institutions

            DN300—DN3000

            Connecting flange material

            Carbon steel

            Grounding the flange material

            Stainless steel 1 crl8ni9ti

            Import protection flange material

            DN65—DNl50

            Stainless steel 1 crl8ni9ti

            DN200~DNl600

            Carbon steel stainless steel 10 1 crl8ni9ti

            Enclosure protection

            DNl5 ~ DN3000 separation type rubber or polyurethane lining sensor

            IP65 or IP68

            Other sensors, bodily form separated type flowmeter and converter

            IP65

            Spacing (separation type)

            Converter distance sensor is generally not more than 100 m

            2, converter technology data:

            The power supply

            communication

            85—265V,45—400Hz

            dc

            11—40V

            Operation keys and display

            touch-tone

            Four film button can be set to choose all parameters, can also use a PC (RS232) of converter set programming;

            3 rows wide Angle of view, wide temperature, with backlit LCD display;

            Line 1 shows the flow value;

            Line 2 show that flow units;

            Line 3 shows total flow percentage, total quantity of forward, reverse, total difference, alarm, velocity of flow.

            The magnetic key type

            The selection of two magnetic key is used to display parameters and reset, use PC (RS232) on converter set programming;

            2 rows wide Angle of view, wide temperature, with backlit LCD display:

            Line 1: the magnetic key choice: display flow percentage, total quantity of forward, reverse, total amount, total difference, alarm, velocity of flow.

            Line 2: display traffic.

            Internal integrator

            Total forward, reverse and total difference amount.

            The output signal

            One-way analog output

            Complete isolation, load 600 d or less.When (20 ma);

            Cap: 0-21 ma optional, each lmA;

            Floor: 0-21 ma optional, each 1 ma;

            Forward and reverse flow output way of programming.

            Two-way analog output

            The lower limit for.Or 4 ma, the other with one-way analog output.

            The bidirectional pulse output

            Two lines of the output corresponding to forward and reverse flow, 0 ~ 800 hz frequency, maximum of 1-800 hz optional, each IHz;

            Square-wave or selected pulse width, pulse width limit selected 2.5 s, every 1 ms;

            Passive isolation switch output transistor, can absorb 250 ma of current, voltage 35 v.

            Two-way alarm output

            Alarm (programming) high/low flow rate, air traffic control, fault state, positive, and reverse flow, analog outrange, pulse volume range, small pulse signal excision, output polarity optional;

            With isolation protection switch output transistor, can absorb the current of 250 ma, withstand voltage 35 v. (with pulse output isolation)

            Digital communications

            RS232,RS485,HART

            3, the choice of the lining:

            The lining material

            The main performance

            Zui high medium temperature

            Scope of application

            - size

            The separation type

            Ptfe (F4)

            Is a kind of plastic, stable chemical performance of boiling hydrochloric acid, sulfuric acid, nitric acid and aqua regia, strong alkali and a variety of organic solvents.Not resistant to high velocity fluid fluorine, oxygen, the oxygen corrosion.

            70 ℃

            100 ℃ 150 ℃ (special order)

            1, strong corrosive medium such as strong acid, alkali.2, health, type of medium.

            Fep (F46)

            With F4, abrasion resistance, resistance to negative pressure ability is higher than the F4.

            Same as above

            Fluoropolymer and ethylene (Fs)

            For maximum temperature was lower than those of ptfe, but the cost is low.

            80 ℃

            Poly (neoprene

            1, has excellent flexibility, high break strength, wear-resisting performance is good.2, generally low concentration acid resistance, alkali, salt medium corrosion, oxidation of medium corrosion resistance.

            80 ℃ 120 ℃ (special order)

            Water, sewage and mud pulp weak up to wear and tear.

            Polyurethane rubber

            1, wear-resisting performance is extremely strong.

            2, poor corrosion resistance.

            80 ℃

            Neutral strong wear of slurry, coal slurry and mud

            4, import protection flange and the choice of grounding flange ring (or ground) :

            The flange type

            Comfortable with van

            Grounding the flange ring (or ground)

            Non-conductors is suitable for pipeline, such as plastic pipe, but has the grounding electrode sensor doesn't need.

            Import protection flange

            When the medium has strong wear.

            5, the choice of electrode:

            Electrode materials

            Corrosion resistance and wear resistance

            Stainless steel 0 crl8nil2m02ti

            Used for industrial water, water, sewage with weak corrosive medium, such as applicable to petroleum, chemical, steel and other industrial sectors and, municipal, environmental protection and other fields.

            Hartz alloy B

            Below boiling point for all the concentration of hydrochloric acid have good corrosion resistance, resistant to sulfuric acid, phosphoric acid, organic acids and other non chloride acid, alkali, corrosion of non oxidizing salt solution.

            Hartz alloy C

            Non oxidizing acid such as nitric acid, mixed acid, or a combination of chromic acid and sulfuric acid medium corrosion, oxidation resistance and salts such as Fe, ",,, Cu "or with other antioxidant corrosion, such as higher than normal temperature hypochlorite solution, the corrosion of the water

            titanium

            The sea, all kinds of chloride and hypochlorite, oxidizing acid (including fuming sulfuric acid), organic acid, alkali corrosion.Not a pure resistance reducing acid such as sulfuric acid, hydrochloric acid corrosion, but contains antioxidants such as acid (such as nitric acid, Fc++, Cu++), the corrosion is greatly reduced.

            tantalum

            It has excellent corrosion resistance and glass is similar.Besides fuming sulfuric acid, alkali, cut almost ability - chemical medium (including the boiling point of hydrochloric acid, nitric acid and sulfuric acid l below 50 ℃) of the corrosion.In the alkali diao;Corrosion resistant.

            Platinum/titanium alloy

            Almost can cut - chemical medium, but does not apply to aqua regia and ammonium salt.

            Stainless steel coated with tungsten carbide

            Used for non-corrosive, strong wear medium.

            Note: due to the variety of medium, the corrosion resistance and affected by complex factors such as temperature, concentration, flow velocity and change, so the data in this table is for reference only.Users should choose according to actual situation, should be done when it is necessary to choose the corrosion test of material, such as coupon test.

            11, correct selection:

            Instrument selection is very important work in instrumentation, relevant data show that the instrument in two-thirds of faults in the practical application is instrument error caused by selection or wrong installation, please pay special attention to.

            1, collect data:

            By measurement of body composition;
            Large flow, small flow;
            Z high work pressure;
            , z z high temperature low temperature;

            2, range scope confirmation:

            General industrial use measured medium velocity of electromagnetic flowmeter with 2 ~ 4 m/s advisable, under special circumstances, z low velocity should not be less than 0.2 m/s, high z should be not more than 8 m/s.If the medium containing solid particles, commonly used flow rate should be less than 3 m/s, prevent excessive friction lining and electrode;For viscous flow, the velocity can choose more than 2 m/s, larger velocity help eliminate electrode automatic on the effect of viscous material, to improve accuracy of measurement.

            Under the condition of the range of Q have been identified, according to the velocity V can be decided to the size of the flow meter diameter D, the range of the values calculated by the next type:

            Q = PI D2V / 4
            Q: flow (㎡ / h) D: pipe diameter V: velocity (m/h)

            Electromagnetic flow meter range of Q zui flow value should be greater than expected, the flow of the normal value in a full scale slightly greater than the flowmeter calibration 50 is advisable.

            3And the reference flow range:

            CAL(mm)

            Flow range(m3/h)

            CAL(mm)

            Flow range(m3/h)

            Phi is 15

            0.06 ~ 6.36

            Phi 450

            57.23~5722.65

            Phi 20

            0.11~11.3

            Phi 500

            70.65~7065.00

            Phi is 25

            0.18~17.66

            Phi 600

            101.74~10173.6

            Phi 40

            0.45~45.22

            Phi 700

            138.47~13847.4

            Phi 50

            0.71~70.65

            Phi 800

            180.86~18086.4

            Phi 65

            1.19~119.4

            Phi 900

            228.91~22890.6

            Phi 80

            1.81~180.86

            Phi 1000

            406.94~40694.4

            Phi 100

            2.83~282.60

            Phi 1200

            553.90~55389.6

            Phi 150

            6.36~635.85

            Phi 1600

            723.46~72345.6

            Phi 200

            11.3~1130.4

            Phi 1800

            915.62~91562.4

            Phi 250

            17.66~176.25.

            Phi 2000

            1130.4~113040.00

            Phi 300

            25.43~2543.40

            Phi 2200

            1367.78~136778.4

            Phi 350

            34.62~3461.85

            Phi 2400

            1627.78~162777.6

            Phi 400

            45.22~4521.6

            Phi 2600

            1910.38~191037.6

            4, selection of code:

            specifications

            Pipe size

            Wei measurement and control of the () material: nodular cast iron and stainless steel

            ZW-LDE

            15-2600

            Code name

            Electrode materials

            K1

            316L

            K2

            HB

            K3

            HC

            K4

            titanium

            K5

            tantalum

            K6

            Platinum alloy

            K7

            Stainless steel coating

            Coated tungsten carbide

            Code name

            Lining material

            C1

            teflonF4

            C2

            fepF46

            C3

            Poly fluoro ethyleneFS

            C4

            Poly (butyl rubber

            C5

            Polyurethane rubber

            Code name

            function

            E1

            0.3level

            E2

            0.5level

            E3

            1level

            F1

            4-20Madc,load750 or less Ω

            F2

            0-3khz,5vActive, variable pulse width, the output high frequency effectively

            F3

            RS485interface

            T1

            The normal temperature type

            T2

            High temperature type

            T3

            Ultra high temperature type

            P1

            1.0MPa

            P2

            1.6MPa

            P3

            4.0MPa

            P4

            16MPa

            D1

            220VAC±10%

            D2

            24VDC±10%

            D3

            Lithium battery type

            J1

            A body structure

            J2

            Points body structure

            J3

            Explosion-proof one body structure

            Twelve, design selection and ordering information:

            1, the measured medium: name, composition, status, electrical conductivity and electrical conductivity;

            2, working temperature (℃);

            3, work pressure (Mpa);

            4, the pipe diameter (DN), the smallest, normal, scope of quantity (m3 / h);

            5, corrosion resistance, wear resistance, whether there is a negative pressure;

            6, installation requirements and the environment: a body or fission, signal output, communications, power supply;

            7, installation environment: protection grade and explosion-proof requirements.

            After-sales service commitment:

            1, from the date of signing of the contract, I in the way provided for products of the company offers free maintenance and maintenance service, commitment to lifelong maintenance service;

            2, jiangsu wei measurement and control instrument co., LTD. Sales manager will be in regular contact with customers, understand the usage of products, and solve the problems of the customers to use in the process of produce, free of charge to provide technical support;

            3 the man-made damage is found, the warranty period, our company is responsible for the maintenance, and the resulting maintenance fee;

            4, product quality problems or are not satisfied with product, the user can choose unconditional return, wei tt&c don't charge any fees, appear quality problem, bear the freight back and forth.


            Browse:
            Return To The Top

            分(fen)亯到(dao):

            tlMNq

              1. <noframes id="S_RI8G">
                <noframes id="S_RI8G"><kbd></kbd>