            Compensation conductor

            補償(chang)導線(xian).jpg
            • 補償(chang)導(dao)線.jpg
            Compensation conductor should be divided into extension type and compensation type two kinds, fluori…

            Description:

            An overview, cables:
            Compensation wires and compensation cables, to a certain temperature range (including temperature) with the matched the thermocouple thermoelectric emfs values the same couple or more with insulated wire or cable, use them to connect the thermocouple and measuring devices, to compensate them with the error produced by the temperature change of the thermocouple junction, compensation wires and compensation cables are divided into extension type and compensation type two kinds, fluorine plastic wire or cable and silicon rubber insulation resistance to high temperature compensation is more high temperature resistant, cold resistant, resistant to acid and alkali oil and water, don't delay burning, anti-aging and other advantages, the products are widely used in petroleum, chemical industry, electric power, metallurgy, medicine, textile and other factories and scientific research departments in the temperature measurement and control system.
            Second, the compensating conductor standards:
            GB/T4989-94 (equivalent to the IEC584-3 standard)
            Three, compensation conductor used features:
            1, the highest working temperature conductor: 70 ℃ polyvinyl chloride (PVC) 200 ℃ and 180 ℃ 105 ℃ silicone rubber fluorine plastic meltability polytetrafluoroethylene (PTFE) 260 ℃
            2, the lowest temperature:
            PVC sheathed: fixed installation to 40 ℃, the fixed installation to 15 ℃.Fluorine plastic and silicone rubber sheath: fixed installation - 60 ℃, the fixed installation - 20 ℃.
            3, cable allows bending radius: the minimum armored cable is 6 times of overall diameter;Copper tape screened or steel tape armoured cable minimum 12 times of cable diameter;Fluorine plastic insulation and sheath minimum 10 times of cable diameter.
            Four, compensation conductor should be the basic model and name:

            model

            Products name said

            KX-GS-VV

            PVC insulated PVC sheathed general in dividing precision grade K thermocouple compensating cable

            KX-GS-VVP

            PVC insulated PVC sheathed wire braided total screen precision grade K is commonly used in dividing thermocouple compensating cable

            KX-GS-VPV

            PVC insulated PVC sheathed wire woven on screen in general by the level of precision indexing number K thermocouple with compensation cables

            KX-GS-VPVP

            PVC insulated PVC sheathed wire woven on total screen is usually in dividing precision grade K thermocouple with compensation cables

            KX-HS-FF

            Fluorine plastic insulation and sheath heat by the level of precision index number K thermocouple with compensation cables

            KX-HS-FFP

            Fluorine plastic insulated and sheathed wire braided total screen heat by the level of precision indexing number K thermocouple with compensation cables

            KX-HS-FPF

            Fluorine plastic insulated and sheathed wire weaving on screen heat by the level of precision indexing number K thermocouple compensating cable

            KX-HS-FPFP

            Fluorine plastic insulated and sheathed wire weaving on total screen heat in dividing precision grade K thermocouple compensating cable

            KX-HS-FG

            Fluorine plastic insulation silicone rubber sheath heat by the level of precision index number K thermocouple with compensation cables

            KX-HS-FGP

            Fluorine plastic insulation silicone rubber sheath copper wire braided total screen heat in dividing precision grade K thermocouple compensating cable

            KX-HS-FPG

            Fluorine plastic insulation silicone rubber sheath copper wire woven on screen heat by the level of precision indexing number K thermocouple compensating cable

            KX-HS-FPGP

            Fluorine plastic insulation silicone rubber sheath copper wire woven on total screen heat in dividing precision grade K thermocouple compensating cable

            KX-HS-FV

            Fluorine plastic insulated PVC sheathed heat by the level of precision index number K thermocouple with compensation cables

            KX-HS-FVP

            Fluorine plastic insulated PVC sheathed wire braided total screen heat by the level of precision indexing number K thermocouple with compensation cables

            KX-HS-FPV

            Fluorine plastic insulated PVC sheathed wire woven on screen heat by the level of precision indexing number K thermocouple compensating cable

            KX-HS-FPVP

            Fluorine plastic insulated PVC sheathed wire woven on total screen heat in dividing precision grade K thermocouple compensating cable

            KX-HS-GG

            Silicone rubber insulated and sheathed heat by the level of precision index number K thermocouple with compensation cables

            KX-HS-GGP

            Silicone rubber insulated and sheathed wire weaving total screen heat in dividing precision grade K thermocouple compensating cable

            KX-HS-GPG

            Silicone rubber insulated and sheathed wire weaving on screen heat by the level of precision indexing number K thermocouple compensating cable

            KX-HS-GPGP

            Silicone rubber insulated and sheathed wire weaving on total screen heat in dividing precision grade K thermocouple compensating cable

            Note: 1, the above models only list the KX, other such as SC, KC, EX, BC, TX, JX need to change the first model;
            2, before this Ann model compensating cable type charging "ia";
            3, flame retardant, compensation cable type filling before "out";If you need armoured can refill "22" after the model;If you want to block, can indicate shielding in style: P, P1 tin plated copper wire, copper wire P2 copper strip, P3 lu: su composite film;Conductor for multiple strands of soft core, should inject "R" after the model.
            4, PTFE ZR190 for imported materials, heat-resistant 260 ℃.
            Five, compensation conductor should be the main technical indicators:

            Compensation conductor model

            With thermocouple

            Thermocouple index number

            Compensating lead wire

            Insulating layer coloring

            The anode

            The cathode

            The anode

            The cathode

            SC

            10 - platinum platinum rhodium thermocouple

            S

            SPC (copper)

            SNC (copper, nickel)

            red

            green

            RC

            13 - platinum rhodium platinum thermocouple

            R

            RPC (copper)

            The RNC (copper, nickel)

            red

            green

            KCA

            Nickel chrome - nickel silicon thermocouple

            K

            KPCA (iron)

            KNCA (copper, nickel)

            red

            blue

            KCB

            Kleiner perkins caufield & byers (copper)

            KNCB (copper, nickel)

            red

            blue

            KX

            KPX (nickel chrome)

            KNX (nickel silicon)

            red

            black

            NC

            Nickel chromium silicon - nickel silicon thermocouple

            N

            NPC (iron)

            NNC (copper, nickel)

            red

            grey

            NX

            NPX (nickel chromium silicon)

            NNX (nickel silicon)

            red

            grey

            EX

            Copper nickel chrome - nickel thermocouple

            E

            EPX (nickel chrome)

            ENX (copper, nickel)

            red

            brown

            JX

            Iron, copper and nickel thermocouple

            J

            JPX (iron)

            JNX (copper, nickel)

            red

            The purple

            TX

            Copper, copper nickel thermocouple

            T

            TPX (copper)

            TNX (copper, nickel)

            red

            white

            Note: type the first letter and the thermocouple corresponding to the index, the second letter in "C" said compensation conductor, the letter "X" said compensation conductor should be extended type.SC type can be compensation conductor with R type degree thermocouple.