          1. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

            Ball valve plug-in vortex flowmeter

            5挿入式渦街流量(liang)計(帶(dai)毬(qiu)閥(fa)).png
            • 5挿入(ru)式渦街(jie)流量(liang)計(帶毬閥(fa)).png
            Ball valve plug-in vortex flowmeter is inserted into the pipeline under test center, measurement of …

            Description:

            Products overview:
            ZW - LUCB seriesBall valve plug-in vortex flowmeterIs inserted into the pipeline under test center, the measurement of velocity center to calculate the measured flow of large-caliber flowmeter.If install ball valve in pipe inserted into the mouth, can undertake no depletion disassembly of vortex street flowmeter, runtime in smudgy medium to facilitate regular cleaning and maintenance.Instrument parameters can be long-term stability.Using piezoelectric stress sensor, high reliability, can be in - 20 ℃ ~ + 250 ℃ temperature range.There are standard signal simulation and digital pulse signal output, easy with the computer and digital systems, is a more advanced, the ideal flow meter.
            Second, the working principle:
            ZW - LUCB seriesBall valve plug-in vortex street of vortex street flowmeter measuring head (i.e., small vortex flow sensor) is developed by using the theory of "the karman vortex street". In the vortex measurement header table body, the vertical insert a triangular prism spiral body, namely when the tables are in the medium flows through the body, is in the opposite direction in both sides of the triangular prism alternate with the rules of the karman vortex street, the signal frequency of vortex is made of the piezoelectric element detection head, detected on one side of the separation of the vortex frequency proportional to the flow of the medium speed, see formula f = V * St/d / 1-1.27 d
            Type: f - separation vortex frequency, triangular prism side (Hz);
            St, turow ha is a constant;
            Average flow velocity, V, the pipe (m/s);
            D - the width of triangular prism characteristics, (m);
            D - measuring head diameter, (m).
            Through a lot of experimental test, determine the vortex street instrument of measuring head coefficient k. formula is as follows:
            K0 = f/V
            Type: the head meter coefficient K0 - measurement, (1 / m);
            The speed of measure head V points - points, (m/s).
            Based on the relationship of velocity V and the pipe flow, plug-in vortex flow sensor can be determined under the different pipe meter factor KT (1 / m3), average flow velocity and volume to determine the pipe flow.
            Applications:
            ZW - LUCB seriesBall valve plug-in vortex flow meter used in petroleum, chemical, metallurgical, thermal, textile, paper and other industries of superheated steam and saturated steam, compressed air and gas (oxygen, nitrogen, hydrogen, natural gas, coal gas, etc.), water and liquid (such as: water, gasoline, alcohol, benzene, etc.) of the measurement and control.
            Four, the main features:
            1, using micro power consumption of new and high technology, high technology content, stable performance, high precision, long life, technology and components are imported.
            2, simple structure and strong, have no moving parts, high reliability, long running is very reliable
            3, good seismic performance, zero drift, elimination of the influence of external vibration effectively.
            4, the output is the pulse signal is proportional to the flow, no zero drift,
            5, wide measuring range, range than up to now.
            6, the liquid crystal display, at the same time, the instantaneous flow display, accumulative total, display, frequency, percentage, don't have to take turns to switch.
            7, in situ Settings, convenient parameter adjustment, without hand-held com.
            8, small pressure loss, wide dynamic range, low operating cost, comprehensive energy saving.
            9, density, temperature and pressure compensation calculation, compensation formula online inspection.
            10, 0 to 5 khzpinlv output, 4-20 ma output or HATR communications, Modbus protocol communication, can be connected to the industrial automation system.
            11, according to the requirements can separate sensors and instrument, the fission control and remote control.
            Five, the technical parameters:
            1, the nominal diameter (mm) : 12 ~ 2200 plug-in);
            2, nominal pressure (MPa) : 1.6 4.0;
            3, medium temperature (℃) : piezoelectric: - 40-450 ℃ (protocol order);
            4, ontology materials: 1 cr18ni9ti, (other material supply agreement);
            5, accuracy: + / - 1% R, plus or minus 1.5% R, plus or minus 1 fs.Insert: plus or minus 2.5% R, plus or minus 2.5% FS.
            6, the power supply voltage: sensors: DC + 12 v, + 24 v DC;Transmitter: + 24 v DC;Battery type: 3.6 V batteries;
            7, the output signal, square wave pulse type (not including batteries) : a high level 5 v, or low level 1 v or less;Current: 4 ~ 20 ma;
            8, explosion-proof marks: the Ann model: Exd Ⅱ ia CT2 - CT5 flameproof: Exd Ⅱ CT2 - CT5;
            9, protection level: ordinary IP65;
            10, environmental conditions: temperature - 20 ℃ ~ 55 ℃, relative humidity 5% ~ 90%, atmospheric pressure of 86 ~ 106 kpa;
            11, suitable medium: gas, liquid and steam;
            12, transmission distance sensor: zui up to 4 km, two wire transducer (4 ~ 20 ma) : load resistance Ω 750 or less.

            Six, installation requirements:

            1, the sensor should be installed in a horizontal, vertical, inclined (liquid flow from bottom to top) and its size in the same line.Sensors upstream and down 2, should be configured with a certain length of straight pipe, the straight pipe length should comply with the former 15 ~ 20 d, straight pipe after 5 ~ 1 od demands.

            3, installation of liquid sensor near the pipe should be filled with liquid to be tested.

            4, sensor installation should be avoided on the strong mechanical vibration of pipeline.

            5, the inside diameter of straight pipe, as far as possible consistent with the sensor size, if not consistent, slightly larger than the sensor size should be adopted for the pipeline, the error to 3% or less, not more than 5 mm.

            6, sensor installation should be avoided in the strong electromagnetic interference, the space is little, and maintenance is not convenient.

            Seven, installation steps:
            1, the need to install the flow meter of pipeline is directly above (horizontal line with this requirement), cut a slightly smaller than ф 100 holes, remove the burr;
            2, will be the end of form a complete set with the short tube flange at the top of the hole, keep the short tube and vertical tube, welding firmly;
            3, put gasket, insert the flowmeter, flange connection, if there are ball valve, should first put the ball on the short tube connection is good, then open the ball valve, inserted into the meter;
            4.Ensure more than 15 D before and after the flow of 5 D straight pipe to pipe diameter (D).

            Need to pay attention to during the period of eight, debugging, using question:
            1, flowmeter, on-site installation, maintenance, must abide by the "explosion-proof gas do not open" warnings, and in the open before turn off the power supply.
            2, vortex flow meter used in outdoor, suggestion and side shields.
            3, shall not be arbitrarily fixed part loosen the flowmeter.The protection of the pressure sensor.Users in the use of traffic time, should pay attention to the flow pressure overload value of pressure sensor is rated working pressure of 1.5 times (i.e., medium to high pressure of 1.5 times).Selection should be within the prescribed flow range, prevent overspeed operation, in order to obtain the ideal accuracy and ensure the normal service life.(due to pressure test, purging pipes or exhaust overdrive, and turbine operation in the reverse flow meter can cause damage)
            4 when put into operation, the vortex street flowmeter, should slowly open valve, prevent damage of instantaneous flow and the turbine.Add lubricant should be according to the sign, the number of refueling depends on temperament clean degree, usually 2 ~ 3 times a year.
            5, vortex street flowmeter runtime or alternate internal related parameters are not allowed to open the rear cover, otherwise will affect the normal operation of the meter.

            Nine, note:

            1. The special flange and straight pipe welding can't with the sensor.

            2. When installation should make the flow of sensor mark the direction of flow and the pipe.

            3. Before the installation of sensor and the flange must be put away in sealing ring grooves.The location of the pressure and temperature measurement point, pressure downstream of the sensor in 3 ~ 5 dn, temperature measuring points in the downstream of 5 ~ 8 dn.

            4. When measuring high temperature medium, do not use insulation wrapped around the sensor link rod.

            5. Shielded cable to connect the sensor, should as far as possible away from the interference of strong electromagnetic field.Absolutely not allowed with high voltage cable laying, shielded cable to shorten as far as possible, and shall not be volume, in order to reduce stray inductance, zui big length should be not more than 200 meters.

            6. Before installation of sensors, pipeline cleaning must be conducted.Flow after rinse tube impurities, avoid clogging sensor.Measuring liquid pipe must be full of measured liquid, prevent the interference of bubbles.

            7, measuring gas pipelines to prevent the interference of reservoir fluid.Replace the probe body under the high temperature and high pressure, it must be safe operation, high temperature protection.After cooling step-down replaceable probe at the bottom of the safety conditions.

            Ten, parameter table:

            Nominal menstruation (mm)

            250~1500

            Instrument material

            1Cr18Ni 9Ti

            Nominal pressure (Mpa)

            PN1.6Mpa;PN2.5Mpa

            Measured medium temperature (℃)

            -40~+ 250℃

            Environmental conditions

            The temperature -10~+ 55℃, relative humidity5% ~90%, the atmospheric pressure86~106Kpa

            Precision grade

            The value forPlus or minus 2.5%

            Range than

            ";1:15

            The resistance loss coefficient

            Cd<2.6

            The output signal

            Sensors: pulse frequency signal0.1 ~ 3000Hz Low level≤1V High level≥6V
            Transmitter: two wire system4 ~ 20mADCCurrent signal

            Power supply

            Sensors:,+24VDC
            Transmitter:+24VDC
            Display type: instrument cabin3.2VThe lithium battery

            The signal transmission line

            KVVP3×0.3(three-wire system),2 x 0.3(Two wire)

            Transmission distance

            ≤500m

            Line interface

            Internal threadM20×1.5

            Explosion-proof grade

            ExdIIBT6

            Protection grade

            IP65

            Allow the vibration acceleration

            1.0g

            Eleven, flow range:

            code

            Nominal diameter

            (mm)

            Flow range (m3 / h)

            liquid The body of the

            gas The body of the

            steamed steam

            ZW-LUCB

            250

            100~1000

            1000~8000

            930~8000

            ZW-LUCB

            300

            150~1500

            1500~11500

            1330~11440

            ZW-LUCB

            350

            200~2000

            2000~15600

            1800~15600

            ZW-LUCB

            400

            250~2500

            2500~20000

            2400~20000

            ZW-LUCB

            500

            400~4000

            4000~30000

            3700~31800

            ZW-LUCB

            600

            500~5000

            5000~45000

            5300~45800

            ZW-LUCB

            700

            700~7000

            7000~60000

            7300~62300

            ZW-LUCB

            800

            900~9000

            9000~80000

            9500~81400

            ZW-LUCB

            1000

            1400~14000

            14000~120000

            14800~127200

            Twelve, selection of coding:

            Code name

            CAL

            With ball valve plug-in vortex street flowmeter (wei measurement and control)

            ZW-LUCB 020

            200mm

            ZW-LUCB 025

            250mm

            ZW-LUCB 030

            300mm

            ZW-LUCB 035

            350mm

            ZW-LUCB 040

            400mm

            ZW-LUCB 045

            450mm

            ZW-LUCB 050

            500mm

            --------

            --------

            ZW-LUCB 0200

            2000mm

            Code name

            function1

            N

            No temperature pressure compensation

            Y

            With temperature compensation

            Code name

            Output type

            F1

            4-20mAOutput (two-wire system)

            F2

            4-20mAOutput (three-wire system)

            F3

            RS485Communication interface

            Code name

            Measured medium

            J1

            liquid

            J2

            gas

            J3

            steam

            Code name

            function2

            E

            2.5level

            T1

            The normal temperature

            T2

            The high temperature

            T3

            steam

            P1

            1.6MPa

            P2

            2.5MPa

            P3

            4.0MPa

            D1

            internal3.6VThe power supply

            D2

            DC24VThe power supply

            B1

            Stainless steel

            B2

            Carbon steel

            13, order selection selection guidelines:

            Name and model number of 1, 1), (2) the diameter, flow range, (3) whether or not to bring the attached so that we can correct selection for you, (4) using pressure, (5) the use of medium temperature.

            2, if has been selected by design units in the way of vortex street flowmeter types, please press type vortex flowmeter directly order from our sales department.

            3, when using occasions is very important, or the environment is complex, please try to provide the design drawings and detailed parameters, by wei experts in our audit checks for you.

            After-sales service commitment:

            1, from the date of signing of the contract, I in the way provided for products of the company offers free maintenance and maintenance service, commitment to lifelong maintenance service;

            2, jiangsu wei measurement and control instrument co., LTD. Sales manager will be in regular contact with customers, understand the usage of products, and solve the problems of the customers to use in the process of produce, free of charge to provide technical support;

            3 the man-made damage is found, the warranty period, our company is responsible for the maintenance, and the resulting maintenance fee;

            4, product quality problems or are not satisfied with product, the user can choose unconditional return, wei tt&c don't charge any fees, appear quality problem, bear the freight back and forth.

            Browse: