1. <noframes id="S_RI8G">
      <noframes id="S_RI8G"><kbd></kbd>
          1. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
            0517-86918678
            Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
            Tel:0517-86918678
            Fax:0517-86918679
            Email:zhongweick@https://clubargos.com
            Post Encoding:211600

            Shielding signal lines

            信號屏蔽電(dian)纜.jpg
            • 信號(hao)屏(ping)蔽(bi)電(dian)纜.jpg
            Shielding line is wrapped a layer of the outside of the conductor shielding layer, plays a role of a…

            Description:

            Products overview:
            Shielding line is wrapped a layer of the outside of the conductor shielding layer, plays a role of anti-interference, general shield for the knitting of brass or copper (aluminum), shield grounding when use need, to foreign interference signal is the layer into the earth, and to avoid jamming signal into the inner conductor dry all at the same time reduce the wastage of the transmitted signal.Shielding line is fit for ac rated voltage up to and including 450/750 power electrical appliances, instrumentation and telecommunications equipment, etc.
            This product standards: GB5023-85
            Second, the shielding signal type and name:
            RVV - copper PVF insulation, circular connection soft PVC sheathed wire.
            RVVB - copper core PVC insulated, PVC sheathed flat soft wire connection.
            RVV - 105 ℃, 105 ℃, PVC insulated copper heat-resisting, circular connection soft PVC sheathed wire.
            RVP - 105 ℃ -- 105 ℃ polyvinyl chloride insulated copper heat-resisting, shielding soft wire (cable).
            RVVP - 105 ℃, 105 ℃, PVC insulated copper heat-resisting, shielding the soft PVC sheathed wire (cable).
            RVVB - 105 ℃, 105 ℃, PVC insulated copper heat-resisting, flat connection soft PVC sheathed wire.
            Three, shielding signal lines using features:
            Ac rated voltage: 300/500 to and including 450/750v.
            Wire allowed working temperature for a long time:
            - 25 ~ 70 ℃
            - 25 ~ 105 ℃
            The installation of wire temperature: not less than 15 ℃
            Four, shielding line product structure:

            Five, shielding line size reference data (specification) :
            RVV RVVB 300/500V

            The serial numberSome conclusions by nominal cross section
            (mm2)
            Wire core structureWire reference data

            Dc resistance
            Not when 20 ℃
            Greater than Ω/KM

            The number/single
            Diameter (mm)
            Nominal diameter
            (mm)

            The largest diameter
            (mm)

            The weight of the
            (kg-km)
            12 x 0.7542/0.156.67.646.0026.0
            22 x 0.7542/0.154.2 by 6.65.0 by 7.643.4426.0
            32 x 1.032/0.207.17.855.6619.5
            42 x 1.548/0.208.18.873.4313.3
            52 x 2.548/0.209.811.0110.807.89
            63 x 0.7542/0.157.28.062.7626
            73 x 1.032/0.207.58.472.3919.5
            83 x 1.548/0.208.99.6101.5313.3
            93 x 2.577/0.2010.711.5154.357.89
            104 x 0.7542/0.157.88.677.5926
            114 x 1.032/0.208.49.261.2319.5
            124 x 1.548/0.209.911.0130.9413.3
            134 x 2.577/0.2011.612.5192.487.89
            145 x 0.7542/0.158.79.496.4826.0
            155 x 1.032/0.209.111.0112.2919.5
            165 x 1.548/0.2011.012.0164.2513.3
            175 x 2.577/0.2012.914.0239.057.89