            ZW-LZ series Pipe burst type metal Rotameter Using magnetic sensor, magnetic field change detection …

            Description:

            Productoverview:

            ZW-LZ series Pipe burst type metal Rotameter Using magnetic sensor, magnetic field change detection angle without contact with the international advanced MCU micro processing system, can realize the liquid crystal indicator, and cumulative output distance (4 20mA), HART protocol, the output pulse output, alarm output function, the intelligent transmitter signal with high accuracy and reliability. Can completely replace the imported same type instrument.According to the process requirements of the vertical installation under the upper and upper lower side into the side and the bottom side, threaded connections, clamp connections, horizontal installation installation optional.

            Second, working principle:

            ZW-LZ series flameproof metal tube rotameter is the medium to be measured through a conical measuring tube float from upper and lower ends of the differential pressure generated form the upward force, when the float was immersed in a fluid on the lift is greater than the weight of the float, the float will rise, annulus area increases, the annulus fluid velocity decreased immediately float on the lower end of the differential pressure is reduced, to float upward force also decreases with, until the lift is equal to the weight of the float when immersed in a fluid, the float will stabilize at a certain height. The float position that corresponds to the size of the measured medium flow. A built-in magnet, the float with the medium moves up and down, with the movement of the float magnetic field changes.

            A, for in situ, by rotary magnetic float and the local indicator in the inner magnetic coupling, rotate, and drives the pointer, through the dial indicates the size of the flow.

            B, the intelligent, by a solid state magnetic sensor intelligent indicator in the magnetic field will change into electrical signal output by A/D transform, D/A microprocessor, LCD liquid crystal display to show the size and cumulative flow flow.

            Third, the scope of application:

            ZW-LZ series flameproof metal tube rotameter applicable to all industries complex, harsh environment, small volume and low velocity, a variety of harsh medium conditions of flow measurement and process control. Widely used in petroleum, chemical, power, pharmaceutical, food, water treatment, etc.. The complex, harsh environmental conditions, the flow measurement process and various medium conditions in.

            Four, instrument structure:

            ZW-LZ series flameproof metal tube rotameter is mainly composed of a measuring device and the indicator consists of two parts, according to the different ways of connection can be divided into vertical and horizontal installation two installation.

            Measuring device part

            1 basic types: wetted parts material 0Cr19Ni9, suitable for liquid measurement;

            2, anti-corrosion type: Teflon lined, suitable for measuring the corrosive medium;

            3, dips: for medium heat or cooling occasions, jacketed flange DN15, PN1.6;

            4, damping type: suitable for gas measurement.

            Indicator

            1, site type indicator: indicates the instantaneous flow field for;

            2, the remote type: DC signal output of 4 ~ 20mA, realize the remote transmission function;

            3, alarm type: the need for alarm occasions.

            Five, main features:

            1, all metal structure design, strong, simple, high pressure resistance, high temperature resistance, corrosion resistance, long service life;

            2, a short trip, the total height of 250mm, easy to install;

            3, mechanical pointer instructions LCD liquid crystal display instantaneous flow, instantaneous flow, cumulative flow;

            4, intelligent indicator, using foreign signal processing chip, modular design, no hysteresis;

            5, data recovery, data backup, power down protection and fault self diagnosis function;

            6, HART type indicator, two-wire 24VDC power supply, 4-20mA standard current signal output of HART protocol stack;

            7, through the HART communication manipulator configuration and parameters can be adjusted;

            8, with the PC serial connection, through the Windows program, to achieve on-site calibration of the instrument;

            9, can be used in flammable and explosive occasions;

            10, vertical and horizontal, upper lower, bottom side, side into the side such as the installation of a variety of forms, flange or threaded connection.

            Six, technical parameters:

            Measuring range: 1, water (20 C) 6 ~ 200000 l/h; air (0.1MPa 20 C) 0.03 ~ 4000 m3/h;

            2, range: 10:1;

            3, precision grade: 1.5 (Frederick 1.0);

            4, working pressure: DN15 ~ DN50 PN4.0MPa (special 32MPa); DN80 ~ DN200 PN1.6MPa (special 25MPa);

            5 medium temperature: 40 to +120 DEG C (electric transmission type C = 85);

            6, medium viscosity DN15: = 5mPa.s (H15.0 ~ H15.4); 30mPa.s (H15.5 ~ H15.9); DN25: = 250mPa.s; DN50 = 300mPa.s ~ DN150;

            7, liquid crystal display: instantaneous flow rate: 0 ~ 50000;

            8, the cumulative flow rate: 0 ~ 99999999;

            9, output: standard signal: 2-wire 4 ~ 20mA;

            10, pulse signal: Zui small interval 50ms;

            11, the alarm signal alarm relay contact capacity: 1A-30VDC, 0.5A-125VDC or 0.25A-250VAC;

            12, power supply: Standard Type: 24VDC (10.8VDC ~ 36VDC);

            13, AC: 220VAC (85VAC ~ 265VAC);

            14, battery type: 3.6-5.2AH lithium battery;

            15, connection: thread connection type: DIN11851 or the user specified;

            16, electrical interface: M20 * 1.5, PG11, 1/2 NPT;

            17, the overall height: Standard Type: 250mm (vertical);

            18, protection grade: IP65;

            19, explosion proof mark: intrinsically safe: ExiaIICT3 ~ 6; flameproof type: ExdIIBT4 ~ 6.

            Seven, structure classification:

            1, the high temperature structure (G type)

            High temperature structure type (G type) is used for medium temperature is too high or too low and the need to take measures on the insulation of the measuring tube medium flow measurement. The high temperature structure is increased and the distance between the measuring tube indicator to increase heat dissipation and increase the insulation thickness, ensure the working environment temperature indicator in the allowable range. The selection of the "G" type.

            The flow of G type metal tube flowmeter can measure the temperature of -80 DEG -+300 DEG medium.

            The structure of 2, with a damper device (Z type)

            Damper structure type flowmeter for entrance flow (pressure) medium flow measurement is unstable, especially for gas measurement.

            3, jacket type structure (T type)

            Jacket structure for heating or cooling of needs (such as high viscosity and flow measurement of the medium Yi Jiejing).In the jacket by heating or cooling medium, the fluid does not vaporize and crystallization.

            Import and export with thermal medium connection standard to use HG20594-97 DN15 PN1.6 flange, flange connection and other specifications may be marked with production plant, pressure rating jacket for 1.6MPa.

            Jacket structure size FA standard flow meter, flange type flowmeter.

            4, high pressure type structure (Y type)

            High pressure type structure for media pressure is greater than the standard pressure level measurement. At present, Zui high pressure can reach 32MPa. In addition high pressure type flowmeter can provide built-in magnetic filter type, installation height is 350mm. FA, FB and FC type Zui high pressure 10MPa.

            Eighth, conversion indicator:

            The converter is actually the height conversion taper pipe float into the corresponding volume scale. From the output signal: local display and remote signal output type:

            1, local display type: by in situ indicator in the follow-up magnetic float and the inner magnetic coupling, and rotate, and the electric pointer by dial indicating the flow

            2, intelligent remote type, by the intelligent indicator in the follow-up magnetic float and the inner magnetic coupling, rotate, and drives the magnet and the sensing pointer through a magnetic sensor magnetic field change into electrical signals by A/D conversion, digital filter, D/ microprocessor, A output, LCD liquid crystal display, to show the instantaneous flow and cumulative flow rate.

            Nine, product maintenance:

            1, in the process of long-term use, the pipeline inevitably there will be ferromagnetic impurity adsorption on the float, it will float stuck or affect the measurement accuracy, from time to time to clean the sensor float; if the installation of magnetic filters should be cleaned regularly.

            2, the instrument indicator with electronic components, instrument wiring or demolition of housing, to housing screws, must ensure sealing, prevent impurities, or other material into the water, and also to ensure reliable earthing of the meter casing.

            3, the instrument is installed, in use, should pay attention to:

            When the valve is opened to avoid the formation of pressure shock makes the float slamming limiting device, causing damage to the instrument, slowly open the valve!

            The measurement of gas meter is equipped with gas damper, Z to decrease the float concussion; to ensure the stability of the float, a throttle valve can be installed in the instrument export.

            4, for the remote type instrument, we must first ensure that the instrument wiring correctly, keeps power; for dangerous situations, must choose the explosion-proof, and the installation and use of proof required by the.

            Troubleshooting ten fault:

            1, check the alarm set value size SU.

            2, check the deviation set D value can not be too large.

            3, FUN function, logic function is correct. HA-A said the upper limit is logical. LA-A said the lower limit is.

            4, circuit board failure, replace the board.

            5, if the lcd barcode indicates the correct output, no action, the cathode can check the external power and external power supply is connected with the anode of instrument power supply.

            If the wobble in use, according to the jitter amplitude to determine what kind of amplitude jitter. Divided into mild and moderate jitter jitter jitter and jitter.

            1, a slight jitter due to fluctuations caused by the media. Can be used to increase the damping of the way to overcome.

            2: general, moderate jitter caused by medium flow state. For general gas as the medium pressure instability caused by.The regulator or stabilizer to overcome or increase the damping of gas meter.

            3, severe jitter: mainly due to medium gas pulsation, operation pressure instability or give users pressure, temperature, flow meter and the actual state does not have large differences over range instrument.

            Eleven, the installation should follow the following steps:

            1, before installation to process piping, should remove all installed and checked for any transport damage;

            2, in order to prevent in transit, with a rubber band fixed pointer indicator, indicator should open the left cover it gently removed before connection, do not change the pointer position;

            3, open the indicator of the right cover, cable through the cable introducing device, according to the wiring diagram wiring rotation transmitter, pressure screw nut, the cable is fixed, and then tighten the fastening screws around the cover, the indicator of waterproof and dustproof;

            4, upstream and downstream piping and instrument instrument should be the same caliber, flange or threaded connection should be matched with the flange and screw instrument, instrument upstream straight pipe length should be 5 times the nominal diameter of the instrument, the downstream straight pipe length not less than H2 250mm;

            5, due to the use of the instrument measuring mechanism is magnetic transfer, so in order to ensure the performance of rotameter installed around the sensor, at least 100mm, the existence of ferromagnetic material is not allowed;

            6 before installation, instrumentation, piping should be purged, prevent the retention of ferromagnetic material in the pipeline is attached to the instrument, the instrument performance, or even damage the instrument. If unavoidable, should be installed at the entrance of the magnetic filter instrument;

            7, the measurement of gas meter is calibrated in special pressure, if the gas meter in the outlet directly discharged into the atmosphere, will produce a pressure drop in the float, and lead to data distortion. If this is the working conditions, should install a valve in the instrument exports, so that the required flow value is set, when the float to maintain calibration pressure, gas expansion in valve;

            The installation form 8, instrument installation for vertical and horizontal installation, if it is installed in a vertical straight form, should ensure that the instrument is better than 1%; if the level of installation form should ensure that the level of instrument is better than 1%;

            9, installed in the pipeline in the instrument should not be subject to stresses, the instrument should be a proper entrance and exit pipe support, can make the instrument in z stress state;

            10, product and computer related to calibration and other operations, must be in a safe place.

            Twelve, installation notes:

            In order to keep the normal work of the flow meter and can reach a certain accuracy, in the installation of the flow meter should pay attention to the following points:

            1, must be installed vertically in the pipeline without vibration. The fluid flowing through the flow meter and the verticality of bottom-up, less than 2 degree, the level of the installation of horizontal angle less than 2 degree;

            2, in order to facilitate the maintenance and replacement of flowmeter, measuring pipeline cleaning, rotameter installed in the pipeline should be installed on the bypass pipe and bypass valve;

            Straight section 3, the entrance should be 5 times the diameter of the length of straight pipe should be 250mm, export;

            4, if the medium containing magnetic material, magnetic filter should be installed; if containing solid impurities in the medium, should consider adding a filter between valve and pipe;

            5, when used to measure the gas, should ensure that the pressure loss of pipeline pressure not less than 5 times of the flowmeter, in order to make the float stability;

            6, in order to avoid the deformation caused by the flowmeter due to pipe, flange and flange coaxial process pipeline must flow and parallel to each other, to support the pipeline to avoid vibration and reduce flowmeter axial load, control valve in the measurement system should be installed in the downstream of the flowmeter:

            7, the measurement of gas, if the gas is directly discharged to the atmosphere in the meter is to be installed in the valve outlet, instrument export, otherwise it will float in the generated pressure drop caused by the distortion of the data.

            8, the installation of PTFE lining instrument, flange nuts do not arbitrarily asymmetric overdone, so as not to cause PTEF lining deformation;

            9, with a liquid crystal display instrument, to avoid direct sunlight, so as not to reduce the service life of the liquid crystal; with lithium battery powered instruments, to avoid direct sunlight, high temperature (65 DEG C) to reduce the capacity and lifetime of lithium battery.

            13, measuring range and pressure loss:

            Decay path

            Common path

            measuring range

            Zui high pressure loss

            DN (mm)

            DN (mm)

            The air (m3/h)

            Water (L/h)

            The air (KPa)

            Water (KPa)

            Fifteen

            Fifteen

            0.05-0.5

            1.6-16

            Seven

            Six point four

            0.07-0.7

            2.5-25

            Seven point one

            Six point five

            0.11-1.1

            4.0-40

            Seven point two

            Six point five

            0.18-1.8

            6.0-60

            Seven point three

            Six point six

            0.28-2.8

            10-100

            Seven point five

            Six point six

            0.40-4.0

            16-160

            Eight

            Six point eight

            0.70-7.0

            25-250

            Ten point eight

            Seven point two

            1.00-10

            40-400

            Ten

            Eight point six

            1.60-16

            60-600

            Fourteen

            Eleven point one

            Twenty-five

            -

            80-800

            -

            Fourteen

            Twenty-five

            3.00-30

            100-1000

            Seven point seven

            Seven

            4.50-45

            160-1600

            Eight point eight

            Eight

            7.00-70

            250-2500

            Twelve

            Ten point eight

            11-110

            400-4000

            Nineteen

            Fifteen point eight

            Fifty

            -

            500-5000

            -

            Sixteen point two

            Fifty

            18-180

            600-6000

            Eight point six

            Eight point one

            25-250

            1000-10000

            Ten point four

            Eleven

            Eighty

            40-400

            1600-16000

            Twelve point six

            Seventeen

            Eighty

            50-500

            2000-20000

            Fifteen point five

            Six point three

            One hundred

            75-750

            2500-25000

            Seventeen Point Two

            Eight point one

            One hundred

            100-1000

            4000-40000

            -

            Nine point five

            One hundred and twenty-five

            160-1600

            6000-60000

            -

            Ten

            One hundred and twenty-five

            250-2500

            8000-80000

            -

            Sixteen

            One hundred and fifty

            -

            10000-100000

            -

            Twenty


            300-3000

            12-120m3/h

            -

            Twenty


            400-4000

            15-150m3/h

            -

            Twenty-five

            Fourteen, the selection of encoding:

            Specification code

            Encoding instructions

            The name of the factory

            ZW

            Zhongwei control

            Instrument types

            LZ

            Metal tube rotameter

            structural style

            /

            In the next

            H1

            The left into the right

            H2

            Right into the left out

            AA

            The side into the side

            LA

            The bottom side

            S

            Threaded connection

            M

            Clamp connection (sanitary polishing tube)

            Size code

            - XXX

            Cases: Fifteen Express DN15

            The measuring tube material

            R1

            1Cr18Ni9Ti , Three hundred and four

            R0

            0cr18Ni12M02Ti , Three hundred and sixteen

            RL

            316L

            RP

            (PTFE F-lined )

            Ni

            (Hasloy Hastelloy C)

            Ti

            (TitHXium titanium alloy )

            Media type

            L

            liquid

            G

            Gas

              working temperature 

            H1

            - 40 C -100 C

            H2

            - 80 C -250 C

            Rated pressure

            One point six

            1.6MPa

            Four

            4.0MPa

            Sixteen

            16MPa

            Twenty-five

            25MPa

            Additional structure

            O

            nothing

            Z

            Damping type

            T

            Jacket

            H

            High temperature type

            Y

            High pressure type

            Form indicator

            M1

            Local indication

            M2

            Intelligent

            M3

            Intelligent ( Flameproof )

            The output signal in the communication

            N

            nothing

            A

            4-20mA

            H

            4-20mA+Hart

            Alarm controller

            K1

            The upper limit alarm

            K2

            Alarm

            K12

            The upper and lower limit alarm

            Explosion proof type

            E1

            Intrinsically safe EX IaCT5 Square shell

            E2

            Flameproof EXiibt4 Park Housing

            Power supply

            Zero

            24VDC (can be omitted )

            Two

            220VAC

            Three

            Three point six Volt lithium battery

            Fifteen, design selection and ordering information:

            1, please provide the pipe size, wall thickness, material requirements and accuracy requirements;

            2, please provide the liquid or gas, such as the name, commonly used commonly used temperature, working pressure, common flow, density, viscosity etc.;

            3, corrosion proof, should indicate the measured corrosion and concentration etc.;

            4, if there are special to show, please contact our sales department.

            Customer service service commitment:

            1, our series of metal tube flowmeter series product quality problems within twelve months, responsible for free maintenance.

            2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.

            3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.

            4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.

            5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.