            Instructions for Selection of Rotor Flowmeter with Metal Tube for Lithium Battery Power Supply
            • File Name:Instructions for Selection of Rotor Flowmeter with Metal Tube for Lithium Battery Power Supply
            • Add Time:2019-04-12 10:30:21
            • Document Size:
            • Recommendation:
            • Immediately Download:
            Download Instructions:

            Productoverview:
            ZW-LZ series of lithium battery powered metal tube rotameter can realize the liquid crystal indicator, and cumulative output distance (4 ~ 20mA), pulse output, alarm output function, the intelligent signal transmitter and has high precision and reliability, and can completely replace the imported type instrument, and has high cost performance, multi parameter calibration, the power down protection etc..It is widely used in various industries complex, harsh environment, small volume and low velocity, a variety of harsh conditions of medium flow measurement and process control.
            Two, the structure and principle of measurement:

            1, structure:
            ZW-LZ series of lithium battery powered metal tube rotameter is mainly composed of three parts:
            A (Intelligent indicator, indicator, local indicator);
            B, float;
            C, a conical measuring chamber.
            2, the principle of measurement:
            On the lower end of the measured medium from the measuring tube through a conical float generating differential pressure form the upward force, when the float on the lift is greater than immersion float in the fluid weight, the float will rise, annulus area increases, the annulus fluid velocity decreased immediately, float on the lower pressure reduced, to float up with the decrease in stress, until the lift is equal to the weight of the float when immersed in a fluid, the float will stabilize at a certain height.The float position that corresponds to the size of the measured medium flow.A built-in magnet, the float with the medium moves up and down, with the movement of the float magnetic field changes.
            A, for in situ, by rotary magnetic float and the local indicator in the inner magnetic coupling, rotate, and drives the pointer, through the dial indicates the size of the flow.
            B, the intelligent, by a solid state magnetic sensor intelligent indicator in the magnetic field will change into electrical signal output by A/D transform, D/A microprocessor, LCD liquid crystal display to show the size and cumulative flow flow.
            Third, widely used:
            ZW-LZ series of lithium battery powered metal tube rotameter is reliable, low maintenance, long service life; widely used in chemical industry, power generation, food, water treatment etc..The complex and harsh environmental conditions, the flow measurement process and various medium conditions in.
            Four, main features:
            1, all metal structure design, strong, simple, high pressure resistance, high temperature resistance, corrosion resistance, long service life;
            2, a short trip, the total height of 250mm, easy to install;
            3, mechanical pointer instructions LCD liquid crystal display instantaneous flow, instantaneous flow, cumulative flow;
            4, intelligent indicator, using the latest foreign signal processing chip, modular design, no hysteresis;
            5, data recovery, data backup, power down protection and fault self diagnosis function;
            6, HART type indicator, two-wire 24VDC power supply, 4-20mA standard current signal output of HART protocol stack;
            7, through the HART communication manipulator configuration and parameters can be adjusted;
            8, with the PC serial connection, through the Windows program, to achieve on-site calibration of the instrument;
            9, can be used in flammable and explosive occasions;
            10, vertical and horizontal, upper lower, bottom side, side into the side such as the installation of a variety of forms, flange or threaded connection.
            Five, technical parameters:
            1, water measuring range: 2.5 ~ 100000l/h (20 C)
            2, range: 10:1
            3, 1, 1.5, accuracy: 2.5
            4, working pressure: DN15, DN25, DN50, PN4.0MPa, DN80, DN100 to 10.0MPa to PN1.6MPa to 6.4MPa
            5, medium temperature: -40 to 300 DEG C
            6, medium viscosity: DN15: <5mPa - s eta (F15.1 ~ F15.3)
            <30mPa - S (F15.4 - F15.8)
            DN25: <250mPa - s.
            DN50: <300mPa - S - DN150.
            7, the ambient temperature: LCD type: -40 to 85 DEG C
            Pointer type: -40 to 120 DEG C
            8, connection: flange (executive standard DIN2501 or as required by standard flange manufacturing)
            9 meter height: 250mm
            10, cable interface: M20*1.5
            11, power supply: 24VDC two-wire 4 ~ 20mA or 85 ~ 265VAC 50/60Hz (remote type)
            12, alarm output: alarm relay output lower or upper limit of instantaneous flow (contact capacity 5A-250VAC) or open collector output (maximum 100mA-30VDC internal impedance of 100 ohm).
            13, the cumulative output pulse: pulse output, minimum interval of every 10 seconds a pulse (AC) or a pulse every 50 milliseconds.
            14, double liquid crystal display: LCD display, display the instantaneous flow and cumulative flow.
            15: Exia II CT4, explosion-proof.
            16, the measuring tube material: 316 stainless steel (common type) or Teflon liner (corrosion type).
            Six, product maintenance:
            1, in the process of long-term use, the pipeline inevitably there will be ferromagnetic impurity adsorption on the float, it will float stuck or affect the measurement accuracy, from time to time to clean the sensor float; if the installation of magnetic filters should be cleaned regularly.
            2, instrument indicator equipped with electronic components, instrument wiring or demolition of housing, to housing screws, must ensure sealing, prevent impurities, or other material into the water, and also to ensure reliable earthing of the meter casing.
            3, instrument installation, on first use, should pay attention to:
            When the valve is opened to avoid the formation of pressure shock makes the float slamming limiting device, causing damage to the instrument, slowly open the valve!
            The measurement of gas meter is equipped with gas damper, to minimize the shock; to ensure the stability of the float, a throttle valve can be installed in the instrument export.
            4, for the remote type instrument, we must first ensure that the instrument wiring correctly, keeps power; for dangerous situations, must choose the explosion-proof, and the installation and use of proof required by the.
            Seven, structure classification:
            1, the high temperature structure (G type)
            High temperature structure type (G type) is used for medium temperature is too high or too low and the need to take measures on the insulation of the measuring tube medium flow measurement.The high temperature structure is increased and the distance between the measuring tube indicator to increase heat dissipation and increase the insulation thickness, ensure the working environment temperature indicator in the allowable range.The selection of the "G" type.
            The flow of G type metal tube flowmeter can measure the temperature of -80 DEG -+300 DEG medium.
            The structure of 2, with a damper device (Z type)
            Damper structure type flowmeter for entrance flow (pressure) medium flow measurement is unstable, especially for gas measurement.
            3, jacket type structure (T type)
            Jacket structure for heating or cooling of needs (such as high viscosity and flow measurement of the medium Yi Jiejing).In the jacket by heating or cooling medium, fluid vaporization and no crystallization.
            Import and export with thermal medium connection standard to use HG20594-97 DN15 PN1.6 flange, flange connection and other specifications may be marked with production plant, pressure rating jacket for 1.6MPa.
            Jacket type flowmeter structure see FA standard flange type flowmeter and the size of map.
            4, high pressure type structure (Y type)
            High pressure type structure for media pressure is greater than the standard pressure level measurement.At present, the maximum pressure can reach 32MPa.In addition high pressure type flowmeter can provide built-in magnetic filter type, installation height is 350mm.FA, FB and FC type maximum pressure of 10MPa.
            Troubleshooting eight fault:
            1, check the alarm set value size SU.
            2, check the deviation set D value can not be too large.
            3, FUN function, logic function is correct.HA-A said the upper limit is logical.LA-A said the lower limit is.
            4, circuit board failure, replace the board.
            5, if the lcd barcode indicates the correct output, no action, the cathode can check the external power and external power supply is connected with the anode of instrument power supply.
            If the wobble in use, according to the jitter amplitude to determine what kind of amplitude jitter.Divided into mild and moderate jitter jitter jitter and jitter.
            1, a slight jitter due to fluctuations caused by the media.Can be used to increase the damping of the way to overcome.
            2, moderate jitter caused by medium flow state: general.For general gas as the medium pressure instability caused by.The regulator or stabilizer to overcome or increase the damping of gas meter.
            3, severe jitter: mainly due to medium gas pulsation, operation pressure instability or give users pressure, temperature, flow meter and the actual state does not have large differences over range instrument.
            Nine, installation requirements.
            Remove the filler, 1 meter box after check, the meter should be installed vertically in the pipeline without vibration, such as to the level of the installation, the order should be additional instructions.The angle between the line and the plumb line flowmeter center should not exceed 5 degrees.
            In 2, the newly installed pipeline flow meter should be installed before the new pipeline clean metal pipe, if the measured medium containing impurity particles or bubbles, you should install filtering device or exhaust in flowmeter installation, the fluid must be flowing from down to up, if the fluid flow from top to bottom, then the flowmeter can not work.If the measured medium is pulsating flow, it should be appropriate to the size of the buffer device is arranged in the downstream, such as surge tank to eliminate pulsation.
            3, in order to check the meter zero and disassembly and maintenance and debugging, should stop valve and bypass valve installed in the upstream and downstream flow meter.
            4, an instrument according to the provisions after installation, should close the flow meter on the downstream shut-off valve, check again with the two meter instrument wiring, error free, open the two meter power supply is the instantaneous flow rate should be zero.For normal use, you should first open the upstream valve is fully open, with a metal tube flowmeter downstream from the valve slowly adjust the flow, instantaneous flow should change.Stop working when they should close the valve, then close the upstream downstream of the valve.

            Table ten parameters:

            Path

            (mm)

            Flow range

            The pressure loss of KPa

            Water L/h

            Air m3/h

            water

            atmosphere

            The conventional type

            Anti-corrosion type

            The conventional type / anti-corrosion type

            The conventional type

            Anti-corrosion type

            Fifteen

            2.5-25
            4.0-40
            6.3-63
            10-100
            16-160
            25-250
            40-400
            63-630

            2.5-25
            4.0-40
            6.3-63
            10-100
            16-160
            25-250
            40-400

            0.07-0.7
            0.11-1.1
            0.18-1.8
            0.28-2.8
            0.48-4.8
            0.7-7.0
            1.0-10.0
            1.6-16.0

            Six point five
            Six point five
            Six point six
            Six point six
            Six point eight
            Seven
            Eight point six
            Eleven point one

            Five point five
            Five point five
            Five point six
            Five point six
            Five point eight
            Six point one
            Seven point three

            Seven point one
            Seven point two
            Seven point three
            Seven point five
            Eight
            Ten point eight
            Ten
            Fourteen

            Twenty-five

            100-1000
            160-1600
            250-2500
            400-4000

            63-630
            100-1000
            160-1600
            250-2500

            3-30
            4.5-45
            7-70
            11-110

            Seven
            Eight
            Ten point eight
            Fifteen point eight

            Five point nine
            Six
            Six point eight
            Nine point two

            Seven point seven
            Eight point eight
            Twelve
            Nineteen

            Fifty

            630-6300
            1000-10000
            1600-16000

            400-4000
            630-6300
            000-10000

            18-180
            25-250
            40-400

            Eight point one
            Eleven
            Seventeen

            Six point eight
            Nine point four
            Fourteen point five

            Eight point six
            Ten point four
            Fifteen point five

            Eighty

            2500-25000
            4000-40000

            1600-16000
            2500-25000

            60-600
            80-800

            Eight point one
            Nine point five

            Six point nine
            Eight

            Twelve point nine
            Eighteen point five

            One hundred

            6300-63000

            4000-40000

            100-1000

            Fifteen

            Eight point five

            Nineteen point two

            One hundred and fifty

            20000-100000


            600-3000

            Nineteen point two


            Twenty point three

            11, selection table:

            ZW-LZ

            Description (Zhongwei control)


            Code

            indicator

            Z

            Basic type indicator

            D

            The remote type indicator


            Code

            Nominal diameter

            -15

            DN15

            -25

            DN25

            -40

            DN40

            -50

            DN50

            -80

            DN80

            -100

            DN100

            -150

            DN150


            Code

            structural style

            /

            In the next

            H1

            The left into the right

            H2

            Right into the left out

            AA

            The side into the side

            LA

            The bottom side

            S

            Threaded connection

            M

            Quick coupler


            Code

            Body material

            R1

            321 stainless steel

            R4

            304 stainless steel

            R6

            316 stainless steel

            R6L

            316L stainless steel

            Hc4

            Ha C alloy

            Ti

            titanium

            F

            With F46 (PTFE)


            Code

            Type indicator

            M7

            Linear indicator

            M9

            Nonlinear indicator (local pointer display flow)


            Code

            Combination function

            ESK

            24VDC; remote 4-20mA standard current signal

            ESK-Z

            24VDC; remote 4-20mA; LCD display instantaneous and cumulative flow field

            ESK-D

            The power lithium battery; LCD display instantaneous and cumulative flow

            K1

            With an on-line alarm signal

            K2

            With on-line alarm signal

            K12

            With a line and a line alarm signal


            Code

            Explosion proof type

            Ex

            Explosion-proof

            Exd

            Flameproof


            Code

            Measuring medium classification

            L

            liquid

            G

            Gas


            Code

            Increase function

            T

            The measuring tube with a heat / heat insulation jacket

            HT

            More than 120 degrees high temperature medium temperature measurement