          1. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
            0517-86918678
            Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
            Tel:0517-86918678
            Fax:0517-86918679
            Email:zhongweick@https://clubargos.com
            Post Encoding:211600

            Thermal sleeve type double metal thermometer

            5熱(re)套(tao)式雙金(jin)屬溫(wen)度(du)計(ji).jpg
            • 5熱套(tao)式(shi)雙金屬(shu)溫(wen)度(du)計(ji).jpg
            WSS series Thermal sleeve type double metal thermometer Is a kind of field measurement for middle an…

            Description:

            Productoverview:
            WSS series Thermal sleeve type double metal thermometer Is a kind of field measurement for middle and low temperature measuring instrument, can be used for direct measurement of gas, liquid, and vapor temperature. The thermometer from the design principle and structure of waterproof, anti-corrosion, explosion-proof, anti vibration, intuitive, easy reading, no mercury damage, durability and other characteristics. The measurement instrument can replace the other workers.
            Two, work principle:
            WSS series Thermal sleeve type double metal thermometer Is the principle of expansion work in varying degrees of temperature change when using two different metals. Industrial use of double metal thermometer main element is one with two or more metal sheet laminated together to form a multilayer metal sheet. In order to improve the measurement sensitivity of double metal thermometer, usually made of sheet metals of spiral shape. When the multilayer metal sheet temperature changes, each layer of metal expansion or shrinkage range, so that the spiral rolled up or loosen. Since the end of the spiral coil is fixed and the other end and a pointer can rotate freely. Therefore, when the feeling of double sheet metal to temperature changes, in a pointer to the circular indexing on the gauge indicates the temperature to.
            Three, application:
            WSS series Thermal sleeve type double metal thermometer With the installation of all kinds of casing, meet different pressure level requirements. Can be directly measured in various production processes within the range of -80-+500 DEG C liquid, steam and gas and solid surface temperature.
            Four, main features:
            1, the scene display temperature, convenient, safe and reliable, long life and other characteristics.
            2, victims of mercury free, easy reading, strong shock.
            3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance.
            4, core pulling type thermometer can not stop short time maintenance or replacement of movement.
            Five, technical parameters:
            The implementation of standards
            JB/T8803-1998 GB3836-83.
            Other parameters
            Dial diameter: 60100150;
            The accuracy level: (1, 1.5);
            Thermal response time: less than 40S;
            Protection grade: IP55;
            Angle adjusting error: angle adjusting error should not exceed the range of 1.0%;
            Return difference: double metal thermometer to the difference should be less than the absolute value of the basic error limit;
            Repeatability: double metal thermometer repeatability limit should be less than the absolute value of basic error of 1/2.

            Six, matters needing attention
            1, can not be directly screw head;
            2, the length of choice to choose the standard size close to the (integer multiples of 50mm);
            3, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, the general recommended immersion length is greater than 100mm, 0-50 DEG C immersion length range is more than 150mm, to ensure the accuracy of measurement.
            4, double metal thermometer should not be used to open the container medium temperature measurement.
            In 5, storage, installation and transportation, should avoid collision protection tube, do not allow the protection tube bending change, but not the table when using the wrench.
            6 regular inspection, under normal conditions of use should be. In general, every six months.
            7, not allowed to work in the strong vibration environment, so as not to affect the double metal life, electric contact bimetallic thermometer is not allowed in the control loop vibration occasions, so as not to affect the reliability.

            Seven, temperature range:

            The measuring range of C

            Applicable scope

            Industrial and commercial

            Laboratory and small

            -80 ~ +40

            B.

            B.

            -40 ~ +80

            B.

            B.

            0~50

            B.

            B.

            0~100

            B.

            B.

            0~150

            B.

            B.

            0~200

            B.

            B.

            0~300

            B.

            B.

            0~400

            B.

            B.

            0~500

            B.

            B.

            Eight, dimensions:

            form

            D

            A

            B

            E

            D

            Radial type

            One hundred and five

            Twenty-three

            Seventy-three


            With 8

            With 10

            One hundred and fifty-five

            Twenty-three

            Seventy-three


            Axial type

            Sixty-five

            Fifty

            One hundred and ten

            Thirty-four

            One hundred and five

            Fifty

            One hundred and ten

            Thirty-four

            Universal type

            One hundred and five

            Twenty-three

            One hundred and seventy-eight

            One hundred and twenty

            One hundred and fifty-five

            Twenty-three

            One hundred and seventy-eight

            One hundred and twenty

            Electric contact

            Axial type

            One hundred and twenty-eight

            Forty

            One hundred and thirty-five


            Electric contact

            Radial type

            One hundred and twenty-eight

            Seventy-two

            One hundred and fifty

            Forty-two

            Electric contact

            Universal type

            One hundred and twenty-eight

            Forty

            One hundred and seventy-five

            Ninety-eight

            9, models and specifications:

            Model

            Measuring range

            Precision grade

            Protection tube material

            Specifications

            Nominal pressure

            Casing form

            WSS-403S

            -80-+40

            -40-+80

            0-50

            0-100

            0-150

            0-200

            0-300

            0-400

            0-500

            1, 5

            1Cr18Ni9Ti

             

            Three hundred and four

            Three hundred and sixteen

            316L

            Hastelloy C-276

            Seventy-five

            One hundred

            One hundred and fifty

            Two hundred

            Three hundred

            Less than 30MPa

            Threaded connection

            WSS-503S

            WSS-413S

            WSS-513S

            WSS-483S

            WSSX-413S

            WSSX-483S

            WSS-403L

            150-40MPa

            Flange type

            WSS-503L

            WSS-413L

            WSSX-503L

            WSS-483L

            WSS-583L

            WSSX-403L

            WSSX-483L

            Note: Zhongwei and double metal thermometer can be installed with a variety of casing, casing in thermal heat installation form installation casing;
            The protection tube material according to ordering protocol: * said nominal pressure set according to flange pressure rating.

            10, encoding selection:

            Serial number

            WSS


            Double metal thermometer (Zhongwei control)

            Dial diameter

            -3


            Phi 60

            -4


            Phi 100

            -5


            Phi 150

            Dial form

            Zero


            The axial (straight)

            One


            Radial (angle)

            Two


            135 degrees to (an obtuse type)

            Eight


            Universal (angle adjustable type)

            Fixed form

            Zero


            No fixed device

            One


            Movable external thread

            Two


            The movable internal thread

            Three


            Fixed thread

            Four


            Fixed flange

            Five


            Card set screw

            Six


            Sleeve flange

            Type of protection

            S

            L

            Heat (S for screw type and type L flange type)

            W


            Type of protection

            F


            Anti-corrosion type

            The selection of examples:
            Universal type double metal thermometer, dial diameter 100, temperature range of 0 to 400 DEG C, 1.5, M27 * 2 rotatablemale thread length 450mm, WSS-481, 0 ~ L=450, 400 C, M27 * 2, 1.5.

            The design and selection of notes:

            1, model;
            2, precision grade;
            3, temperature range;
            4, fixed form;
            5, the installation form of casing heat;
            6, the inserted length.
            Customer service service commitment:
            1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
            2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
            3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
            4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
            5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


            Browse: