            Post Encoding:211600

            Explosion proof type double metal thermometer

            5防(fang)爆(bao)型(xing)遠傳(chuan)雙金屬溫(wen)度(du)計(ji).jpg
            • 5防爆型遠傳雙金屬(shu)溫度(du)計.jpg
            WSSB series Anti Burst type double metal thermometer Is a suitable measurement, low temperature fiel…

            Description:

            Productoverview:
            WSSB series Anti Burst type double metal thermometer Is a suitable measurement, low temperature field detection instrument, can be used to directly measure the temperature of the gas, liquefied. Compared with the domestic similar products: precision instrument level reaches 1, the meter shell made of anti-corrosion materials, its temperature can reach 200 DEG C, Zui low -40 C. Flange type structure, double sealing ring, the anticorrosion, good waterproof performance. The protective tube welded by automatic argon protection tube, solid weld, small intergranular corrosion.The dial is aluminum oxide printing plate, clear surface styling. For the adjustable pointer.
            Two, work principle:
            <strong> Anti</strong> WSSB series Burst type double metal thermometer Is the principle of expansion work in varying degrees of temperature change when using two different metals. Industrial use of double metal thermometer main element is one with two or more metal sheet laminated together to form a multilayer metal sheet. In order to improve the measurement sensitivity of double metal thermometer, usually made of sheet metals of spiral shape. When the multilayer metal sheet temperature changes, each layer of metal expansion or shrinkage range, so that the spiral rolled up or loosen. Since the end of the spiral coil is fixed and the other end and a pointer can rotate freely. Therefore, when the feeling of double sheet metal to temperature changes, in a pointer to the circular indexing on the gauge indicates the temperature to.
            Three, application:
            <strong> Anti</strong> WSSB series Burst type double metal thermometer With the installation of all kinds of casing, meet different pressure level requirements. Can be directly measured in various production processes within the range of -80-+500 DEG C liquid, steam and gas and solid surface temperature.
            Four, main features:
            1, the scene display temperature, convenient safe and reliable, long service life;
            2, a variety of forms, can meet different requirements. Victims of mercury free, easy reading, strong shock.
            3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance.
            4, core pulling type thermometer can not stop short time maintenance or replacement of movement.
            5, integrated with axial type, radial type, 135 type, universal type, complete varieties, suitable for various on-site installation need.
            Five, technical parameters:
            The implementation of standards
            JB/T8803-1998 GB3836-83.
            Other parameters
            Dial diameter: 60100150;
            The accuracy level: (1, 1.5);
            Thermal response time: less than 40S;
            Protection grade: IP55;
            Angle adjusting error: angle adjustment error should not exceed the range of 1%;
            Return difference: double metal thermometer to the difference should be less than the absolute value of the basic error limit;
            Repeatability: double metal thermometer repeatability limit should be less than the absolute value of basic error of 1/2.

            Six, matters needing attention:
            1, in storage, installation, use and transport process, to avoid the collision protection tube, prohibit the protection tube bending and deformation.
            2, installation, non twist instrument shell.
            3, the instrument shall work normally in the -30 to 80 DEG C ambient temperature.
            4, the instrument can often work in the temperature scale range 1/2 ~ 3/4.
            5, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, this is done in order to ensure the accuracy of measurement.
            6, do not use media exposure in measuring container.
            7, the use of the process should pay attention to check in time, probably in about 6 months.


            Seven, temperature range:

            The measuring range of C

            Applicable scope

            Industrial and commercial

            Laboratory and small

            -80 ~ +40

            B.

            B.

            -40 ~ +80

            B.

            B.

            0 ~ 50

            B.

            B.

            0~100

            B.

            B.

            0~150

            B.

            B.

            0~200

            B.

            B.

            0 ~ 300

            B.

            B.

            0~400

            B.

            B.

            0~500

            B.

            B.

            Eight, dimensions:

            form

            D

            A

            B

            E

            D

            Radial type

            One hundred and five

            Twenty-three

            Seventy-three


            With 8

            With 10

            One hundred and fifty-five

            Twenty-three

            Seventy-three


            Axial type

            Sixty-five

            Fifty

            One hundred and ten

            Thirty-four

            One hundred and five

            Fifty

            One hundred and ten

            Thirty-four

            Universal type

            One hundred and five

            Twenty-three

            One hundred and seventy-eight

            One hundred and twenty

            One hundred and fifty-five

            Twenty-three

            One hundred and seventy-eight

            One hundred and twenty

            Electric contact

            Axial type

            One hundred and twenty-eight

            Forty

            One hundred and thirty-five


            Electric contact

            Radial type

            One hundred and twenty-eight

            Seventy-two

            One hundred and fifty

            Forty-two

            Electric contact

            Universal type

            One hundred and twenty-eight

            Forty

            One hundred and seventy-five

            Ninety-eight

            9, models and specifications:

            Model

            The measuring range of C

            Precision grade

            Protection tube material

            Specifications

            Mounting device

            WSSB-410

            -80-+40

            -40-+80

            0-50

            0-100

            0-150

            0-200

            0-300

            0-400

            0-500

            One point five

            1Cr18NI9Ti

            Three hundred and four

            Three hundred and sixteen

            316L

            Hastelloy C-276

            H.AIIoyc-276

             

            Seventy-five

            One hundred

            One hundred and fifty

            Two hundred

            Three hundred

            Four hundred

            Five hundred

            Seven hundred and fifty

            One thousand

            No screw fixing device

            WSSB-480

            WSSB-411

            Movable external thread

            WSSB-481

            WSSB-412

            The movable internal thread

            WSSB-482

            WSSB-413

            Fixed flange

            WSSB-483

            WSSB-414

            Fixed thread

            WSSB-484

            WSSB-415

            Card set screw

            WSSB-485

            WSSB-416

            Sleeve flange

            WSSB-486

            Example: Zhongwei flameproof universal type double metal thermometer, a regulating upper temperature range Zero ~Four hundred C, protective tube Three hundred and sixteen Insert, length 300mm WSSX-481BM 0 ~ Four hundred C L=300Protection tube Three hundred and sixteen .

            Ten, the selection of encoding:

            Serial number

            category

            Specifications

            Explain

            WSS

            B

            Explosion proof type

            Double metal thermometer (Zhongwei control)

            Dial diameter

            -3


            Phi 60

            -4


            Phi 100

            -5


            Phi 150

            Dial form

            Zero


            The axial (straight)

            One


            Radial (angle)

            Two


            135 degrees to (an obtuse type)

            Eight


            Universal (angle adjustable type)

            Fixed form

            Zero


            No fixed device

            One


            Movable external thread

            Two


            The movable internal thread

            Three


            Fixed thread

            Four


            Fixed flange

            Five


            Card set screw

            Six


            Sleeve flange

            Type of protection

            -


            Ordinary type

            W


            Type of protection

            F


            Anti-corrosion type

            Eleven, Design selection and ordering information:
            1, model;
            2, precision grade;
            3, temperature range;
            4, electric contact position adjustment;
            5, fixed form;
            6, the inserted length. 
            Customer service service commitment:
            1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
            2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
            3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
            4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
            5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


            Browse:
            Return To The Top

            分亯(xiang)到:

            YcSIT

              1. <noframes id="S_RI8G">
                <noframes id="S_RI8G"><kbd></kbd>