            Intelligent dual input display regulator

            5智能(neng)雙(shuang)輸(shu)入(ru)顯(xian)示調(diao)節(jie)儀(yi)XMBA-7000.png
            • 5智(zhi)能(neng)雙輸(shu)入(ru)顯示調(diao)節儀(yi)XMBA-7000.png
            Intelligent double input display apparatus used on its own research and development, integrated circ…

            Description:

            Products overview:

            ZW - XMBA seriesIntelligent display apparatus with two inputsDeveloped by using the, entrust integrated circuit manufacturers custom application-specific integrated circuit production, it not only collected all kinds of monitoring instrument in the automatic control system for most of the functionality, and integrates the CPU, I/D interface, RS485 and RS232 communication interface, EPROM and D/A conversion circuit, supplemented by eclecticism, elaborate, repeated debug software system using this instrument has the following characteristics.

            1. ZW - XMBA series intelligent double input display apparatus hardware are greatly reduced, the system structure is relatively simple, the technology is improved significantly, did not fly line, no debug potentiometer, all the parameters setting, instrument calibration function are all through the keyboard performed by software.

            2. ZW - XMBA series intelligent double input display apparatus can be set four alarm output, alarm method can reach more than 10.Can be arbitrarily assigned to a primary input or vice lose, also can be the difference in value assigned to the main input and vice or assigned to the main input and vice and values or assigned to the main input and vice input values.

            3. ZW - XMBA series intelligent display apparatus with two inputs can be set to one of the switch to the other three switch monitor have a choice, and to realize intelligent sound and light alarm function with a quieter time.

            4. ZW - XMBA series intelligent double input display apparatus optional add two or three road D/A output, can be arbitrarily assigned to A primary input or input use, analog output value of zero and full numerical range can be displayed in any setting.The output can be photoelectric isolation, provide 5 v and 24 two constant-voltage source output.

            5. Any complex control, regulation, alarm, output, and other functions, can be the instrument has simple operation, set the pressure to be password protected, use it into a fool type instrument, the operator will not be able to modify the parameters of the locked.You set by the user at all levels of the four categories of one hundred kinds of anti-interference mode, can adapt to various environmental interference sources.

            Second, the main functions:

            1, the input signal for the input of various index number of thermocouple, heat resistance, all kinds of standard linear signal, (double input signal must be the same) or thermal resistance (Pt100) and linear signal (please specify when ordering.

            2, display process measured in any setting range (1999 ~ 9999, 9999 ~ 1999, the decimal point 0 ~ 3 bits) or 0 ~ 100%.

            3, double amount of input process instructions, two article simulated the triple according to instructions, etc.

            4, double input display range can be set respectively.

            5, the main input and vice input display value could add and subtract divide.

            6, the main input after comparing with vice between input can control relay action.

            After 7, break, break, break even the state of the output.

            8, break, break, break after I used in the state of the relay type control, maintain function.

            Three, technical parameters:

            1, the accuracy of measurement: plus or minus 0.5% FS + 1 d±0.2%FS±1d;

            2, alarm way: on the ceiling, floor, floor, poor poor last time, next time, double difference, OK, the absolute value method, etc.;

            3, the analog output precision: plus or minus 0.2% FS.

            4, analog output driven load impedance;

            Current signal: 0 ~ 10 ma acuity 1.5 K Ω;4 ~ 20 ma 750 Ω p;

            Voltage signal: 0 ~ 5 v, 1 ~ 5 v output impedance 1 Ω or less;

            5, analog input impedance;

            Current signal: 50 or less Ω;A voltage signal: 50 k or Ω;

            6, the relay contacts capacity: AC220V, 3 a (impedance load)

            7, the parameters of the set when the power is keeping time: 20 years or more;

            8, dielectric strength: ac voltage 1500 v, 1 minute;

            9, insulation impedance: more than 50 m Ω;

            10, power supply: AC220V, 50 hz, 6 w or 24 v or less;

            11, working environment requirement: temperature 0 ~ 50 ℃, relative humidity of 85% or less without corrosive gas, no vibration.

            Four, according to instructions:

            1. Double screen

            (left) on the digital tube display the main input signal measurement

            Discharge (right) deputy input measurement signals, the digital tube display or display operation value between the main input and vice

            Article 2. The double screen + single simulation

            (left) on the digital tube display the main input signal measurement

            Discharge (right) deputy input measurement signals, the digital tube display or display operation value between the main input and vice

            Simulation shows that the amount of input signal process %, the display of the switch between main channel and using the key implementation

            Article 3. The single + double simulation

            Digital tube display the main input signal or vice input measurement signal

            According to switch between main channel and use the add button

            The first article 36 line simulation in the form of percentage according to the main input signal measurement

            The second article 36 line simulation to displayed in percentage of input signal measurement

            Article 4. The double screen + double simulation

            (left) on the digital tube display the main input signal measurement

            Discharge (right), digital tube display vice input signal measured or operation value between the main input and vice

            Article left simulation in the form of percentage according to the main input signal measurement

            Article right analog signal measured at displayed in percentage of input

            5. Light

            A lamp or J1 lamp, SP1 is alarm indicator lights

            E light or J2 light, is SP2 alarm indicator lights

            Lamp or J3 lamp, B is SP3 alarm indicator lights

            C lights or J4 lights, is SP4 alarm indicator

            Five, the selection table:

            ZW-XMBA——instructions
            Design sequence7In the intelligent double input display apparatus (wei measurement and control)
            Display mode1single
            2Double screen
            3Single + single beam
            4Single + double beams
            5Double screen + single beam
            6Double screen + double beams
            7Three screen display
            8Display and small signal for prescribing resection (please indicate the order)
            Input mode1Main input as thermocouple (K, E, S, B, J, T, R, N)
            2Main input as of resistance (Pt100, Cu100, Cu50, BAz, BA, G)
            3Main input with the current or voltage (0 ~ 10 ma, 4 ~ 20 ma, 0 to 20 mv, 0 ~ 100 mv, 0 ~ 500 mv, 0 ~ 5 v, 1 ~ 5 v)
            4Main input to Pt100, as a pair of input current or voltage (order) indicated
            Output control output and adjusting way (switch)0There is no relay output
            1One relay (arbitrarily assigned to the main input or vice operation value) between the input or the deputy
            22 relay (arbitrarily assigned to a primary input or vice input or vice operation between value)
            33 relay (arbitrarily assigned to a primary input or vice input or vice operation between value)
            44 relay (arbitrarily assigned to a primary input or vice input or vice before operation value)
            Additional features0No additional features
            1With a broken accidentally, fault resistance, break line state output
            Overall dimensionsHHorizontal type 160 x 80Opening 152 x 76
            VVertical 80 x 160Opening 76 x 152
            FThe way to 96 by 96Opening 92 x 92
            QThe way to 72 by 72Opening 68 x 68
            Analog outputAThe main input or vice input analog output independently
            B(the main input - vice) x (Lup - ")
            C(main input - vice) + x (Lup - ") + display displacement PFS
            DThe main operation value of the input and vice input output
            EMain input and vice or independent analog output
            FAnalog output special requirements
            For the 24 v dc power supplyPDefault is no 24 v dc power supply output
            With 24 v dc output power (to do two wire transducer power)
            Communication interfaceTThe default is not to bring a communication interface
            With RS485 and RS232 communication interface
            Power supply

            K

            W

            The default is 220 vac
            Switching power supply of 85 ~ 260 vac
            Switching power supply 18 to 36 VDC or 18 ~ 36 vac

            After-sales service commitment:

            1, our company sold by wei measurement and control products quality problems within twelve months, responsible for free maintenance.

            2, the warranty period, any quality problems such as the products of our company, my company is responsible for free repair or replacement.

            3, the warranty period, such as user improper use, damaged products, my company is responsible for the maintenance, charge damage parts cost.

            4, after the warranty period appear quality problem, my company is responsible for the maintenance, charge damage parts cost.

            5, such as user need to my company site services, to users in the province I company service personnel to reach the site within 12 hours, fujian association of foreign languages and user reach the site within 48 hours.