            Rosemount 3051L Flanged Installed Level Transmitter

            儸(luo)斯(si)矇特3051L灋(fa)蘭安裝液(ye)位(wei)變(bian)送器(qi).jpg
            • 儸斯矇(meng)特(te)3051L灋蘭安(an)裝液(ye)位變(bian)送(song)器.jpg
            Ross Monte 3051L flange mounted liquid level transmitter Due to the adoption of ASIC amplifier desig…

            Description:

            Productoverview:
            Ross Monte 3051L flange mounted liquid level transmitter Due to the adoption of ASIC amplifier design to make the packaging becomes small, and the miniaturization of the membrane structure and the flange of the box, this type of weight dropped to half of the original type. ASIC design not only reduces the number of parts, but also improve the reliability of the amplifier.
            Two, work principle:
            When working, the high and low pressure side of the diaphragm and the filled liquid transmit the process pressure to the filling liquid filled liquid, then transmits the pressure to the center of the sensing diaphragm sensor. The sensing membrane is a elastic element of tension, compression and displacement with the change (for GP gauge transmitter, atmospheric pressure as applied in the low voltage side of the sensing membrane.). The AP absolute pressure transmitter, low voltage side always maintain a reference pressure. The sensing membrane Zui large displacement is 0.004 inches (0.1 mm), and the displacement is proportional to pressure. The capacitor plates on both sides of the diaphragm position detection sensor. The difference between the capacitance sensing diaphragm and capacitor plate is converted to the corresponding voltage or current, HART (high speed digital data highway addressable remote transmitter output signal).
            Third, widely used:
            For the measurement of gas, liquid and vapor pressure, and then turn it into a current signal output 4-20mADC. Can HART375, 475 hand operator to communicate with each other, setting and monitoring through them.
            Fourth, the main features:
            1, 5 years of continuous work without adjustment;
            2, the temperature effect is negligible;
            Influence of static pressure can be ignored;
            3, one-way impact: 100 thousand consecutive unidirectional overvoltage overvoltage after the experiment affect the amount of less than 0.03%;
            4, improve the self diagnosis function;
            5, small, lightweight (standard 3.9kg);
            6, static effects are neglected:
            When a static pressure (pressure), resonant beam deformation two shape, size and material identical to the same, so the frequency change is consistent, so the deviation automatically cleared (figure similar formula and temperature influence).
            7, excellent properties of unidirectional overvoltage:
            The liquid membrane and the membrane using corrugated box body processing technology of the original, so that the external pressure increases to a certain value, the film can fully contact with the body, silicone oil is transferred to the sensor pressure no longer increase with the increase of external force, so as to achieve the protective effect on sensor.
            Five, technical parameters:
            The 1. level measurement accuracy of 0.075%;
            2. calibration range from 0.25inH2O to 8310inH2O;
            3. flat film chip, 2-, 4-, and inch extend type diaphragm;
            4. kinds of filling liquid optional, can meet the requirements of different applications;
            5. clever and lightweight, easy installation and maintenance;
            6. liquid material: 316L stainless steel, Hastelloy, tantalum.
            Six, selection table:

            Model

            Product name

            3051L

            Flange mounted liquid level transmitter

            Code

            Pressure range (range /zui Small range)

            Two

            -250 to 250inH Two O/2.5H Two O (-62.2KPa to 62.2KPa/0.62KPa)

            Three

            -1000 to 1000inH Two O/10H Two O (-248KPa to 248KPa/2.5KPa)

            Four

            -8310 to 8310inH Two O/83.1H Two O (-2070KPa to 2070KPa/20.7KPa)

            Code

            output

            A

            4-20mA Based on a HART Digital signal protocol

            M

            Low power consumption, 1-5VDC Based on a HART Digital signal protocol ( 0.8-3.2VDC Output option code C2 )

            F

            FF Bus

            W

            PROFIBUS

            Code

            Diaphragm size

            Material Science

            Extended length

            Notes

            G0

            2in./DN 50

            316L SST

            Only the plane type

            Extension with diameterEighty The Conduit

            Size. Of Forty Pipe size,

            Please consult factory.

            H0

            2in./DN 50

            Hastelloy C-276

            Only the plane type

            J0

            2in./DN 50

            tantalum

            Only the plane type

            A0

            3in./DN 80

            316L SST

            Plane type

            A2

            3in./DN 80

            316L SST

            2in./50mm

            A4

            3in./DN 80

            316L SST

            4in./100mm

            A6

            3in./DN 80

            316L SST

            6in./150mm

            B0

            4in./DN 100

            316L SST

            Plane type

            B2

            4in./DN 100

            316L SST

            2in./50mm

            B4

            4in./DN 100

            316L SST

            4in./100mm

            B6

            4in./DN 100

            316L SST

            6in./150mm

            C0

            3in./DN 80

            Hastelloy C-276

            Plane type

            C2

            3in./DN 80

            Hastelloy C-276

            2in./50mm

            C4

            3in./DN 80

            Hastelloy C-276

            4in./100mm

            C6

            3in./DN 80

            Hastelloy C-276

            6in./150mm

            D0

            4in./DN 100

            Hastelloy C-276

            Plane type

            D2

            4in./DN 100

            Hastelloy C-276

            2in./50mm

            D4

            4in./DN 100

            Hastelloy C-276

            4in./100mm

            D6

            4in./DN 100

            Hastelloy C-276

            6in./150mm

            E0

            3in./DN 80

            tantalum

            Only the plane type

            F0

            4in./DN 100

            tantalum

            Only the plane type


            Code

            Installation flange size

            Rating

            Material Science

            Applicable to high voltage side of diaphragm size

            M

            2in.

            One hundred and fifty level

            carbon steel

            2 in./DN50

            A

            3in.

            One hundred and fifty level

            carbon steel

            3 in./DN80

            B

            4in.

            One hundred and fifty level

            carbon steel

            4 in./DN100

            N

            2in.

            Three hundredlevel

            carbon steel

            2 in./DN50

            C

            3in.

            Three hundredlevel

            carbon steel

            3 in./DN80

            D

            4in.

            Three hundredlevel

            carbon steel

            4 in./DN100

            P

            2in

            Six hundredlevel

            carbon steel

            2 in./DN50

            E

            3in.

            Six hundredlevel

            carbon steel

            3 in./DN80

            X

            2in.

            One hundred and fifty level

            SST

            2 in./DN50

            F

            3in.

            One hundred and fifty level

            SST

            3 in./DN80

            G

            4in.

            One hundred and fifty level

            SST

            4 in./DN100

            Y

            2in.

            Three hundredlevel

            SST

            2 in./DN50

            H

            3in.

            Three hundredlevel

            SST

            3 in./DN80

            J

            4in.

            Three hundredlevel

            SST

            4 in./DN100

            Z

            2in.

            Six hundredlevel

            SST

            2 in./DN50

            L

            3in.

            Six hundredlevel

            SST

            3 in./DN80

            Q

            DN 50

            PN 10-40

            carbon steel

            2 in./DN50

            R

            DN 80

            PN 40

            carbon steel

            3 in./DN80

            S

            DN 100

            PN 40

            carbon steel

            4 in./DN100

            V

            DN 100

            PN 10/16

            carbon steel

            4 in./DN100

            K

            DN 50

            PN 10-40

            SST

            2 in./DN50

            T

            DN 80

            PN 40

            SST

            3 in./DN80

            U

            DN 100

            PN 40

            SST

            4 in./DN100

            W

            DN 50

            PN 10/16

            SST

            4 in./DN100


            Code

            The process of oil filling -High pressure side

            Temperature limit

            A

            Syltherm XLT

            -75 to One hundred and fifty C (-102 to302 ~ F)

            C

            D.C.704 silicone oil

            Zero to Two hundred and five C (32 to401 degrees F)

            D

            D.C.200 silicone oil

            -45 to Two hundred and five C (-49 to401 degrees F)

            H

            Inert liquid

            -45 to One hundred and seventy-five C(-49 to 347 degrees F)

            G

            Glycerin and water

            -15 to Ninety-five C (5 to 203 degrees F)

            N

            Neobee M-200

            -15 to Two hundred and five C (5 to 401 degrees F)

            P

            Propylene glycol and water

            -15 to Ninety-five C (5 to 203 degrees F)


            Code

            option


            Header

            M (1)

            Linear meter, 0-100% scale

            M3 (1)

            The special calibration table, specify the range

            M4 (1)

            LCD Header, 0-100%

            M7 (1)

            LCD First, linear, special set


            Hazardous area certification

            E5

            The Canadian Standards Association (CSA) Flameproof certification

            I5 (2)

            Factory mutual (FM) Non flammable and safety certification

            K5

            Factory mutual (FM) Flameproof and intrinsically safe comprehensive certification

            C5 (3)

            Canada certification industry and Science ( Only Canada )

            C6 (2)

            I6 and E6 Combination, CSA Flameproof and intrinsically safe certification


            ( Requirement Zui High power supply voltage 42.4Vdc)

            K6

            CSA/CENELEC Flameproof and intrinsically safe certification

            EF (4)

            China NEPSI, GB Flameproof certification standard

            EF (2) (4)

            China NEPSI, GB Standard essential safety certification

            E4

            Japanese industrial standard (JIS) Flameproof certification

            E7

            The Standards Association of Australia (SAA) Flameproof certification

            E8

            CESI/CENELEC Flameproof certification

            I1 (2)

            BASEEFA The essence of security authentication

            I7 (2)

            The Standards Association of Australia (SAA) The essence of security authentication

            I8 (5)

            CESI/CENELEC The essence of security authentication

            N1 (2)

            BASEEFA N Type certification

            N7

            The Standards Association of Australia (SAA) Non flammable safety certification

            IC (2)

            SEV The essence of security authentication


            Other options

            W5

            copper O Ring type, used for vacuum occasions (non wetted parts)

            Q4

            Check data sheet

            Q8 (6)

            Material traceability, in accordance with EN 10204 3.1B

            L4

            316 SST Flange and bolt joints

            V1

            Inverting output

            V2

            4-20mV test signal

            V3

            20-100mV test signal

            Z1 (7)

            4- Line, 0-20mA output

            Z2 (7)

            4- Line, 0-16mA output

            Z3 (7)

            4- Line, 0-10mA output

            F_

            From table flush connection options in selecting a set of code

            Seven typical models:

            3051L2AG0RD21AAK5M5Q4
            3051L2AH0KD21AAM5
            3051L3AA0FD21AB



            Browse: