          1. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
            0517-86918678
            Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
            Tel:0517-86918678
            Fax:0517-86918679
            Email:zhongweick@https://clubargos.com
            Post Encoding:211600

            XLPE Insulated Power Cable

            交(jiao)聯(lian)聚(ju)乙(yi)烯(xi)絕緣(yuan)電(dian)力(li)電纜.jpg
            • 交聯聚乙烯絕緣(yuan)電(dian)力(li)電纜.jpg
            XLPE insulated power cables are manufactured in accordance with the national standard GB/T12706-2002…

            Description:

            A, product standards and scope:
            XLPE insulated power cable According to People's Republic of China's national standard GB/T12706-2002 production, the standard equivalent international standard IEC60502-1997, is suitable for AC rated voltage 35kV and below middle and low voltage power distribution line.
            Executive standard: GB12706-91 IEC502, IEC332-3 is equivalent to the standard
            Usage: suitable for rated voltage U0/U and below 26/35KV for transmission and distribution system.
            Characteristics: the working temperature of cable core: the maximum permissible does not exceed 90 degrees
            The core circuit temperature not exceeding 250 degrees, not more than 5 seconds.
            Two, XLPE insulated power cable Bending radius:
            Single core cable bending radius: 20 + 5% (d+D);
            Multi core cable bending radius: 15 + 5% (d+D).
            Three, XLPE insulated power cable Laying temperature:

            ModelNameApplicable scope
            YJV
            YJLV
            ZR-YJV
            ZR-YJLV
            Flame retardant and non flame retardant copper or aluminum conductor XLPE insulated, PVC sheathed power cableFor laying indoors and outdoors, can withstand external mechanical force certain occasions, the single core cable cannot be laid in magnetic ducts.
            YJV22
            YJLV22
            ZR-YJV22
            ZR-YJLV
            Flame retardant and non flame retardant copper or aluminum conductor XLPE insulated, PVC sheathed power cableFor laying underground, able to bear external mechanical forces, but unable to bear large tension.
            YJV32
            YJLV32
            ZR-YJV32
            ZR-YJB32
            Flame retardant and non flame retardant copper or aluminum conductor XLPE insulated, PVC sheathed fine steel wire armoured power cableSuitable for use in water or drop area, able to bear external mechanical force and pulling force.

            Four, <strong> XLPE power cable</strong> specifications:

            Core numberCopper conductorAluminum conductor
            YJV, ZR-YJVYJV22, ZR-YJV22YJLV, ZR-YJLVYJLV22, ZR-YJLV22
            One1.5-50010-50010-50010-500
            Two1.5-3004-24010-30010-240
            Three1.5-3002.5-24010-30010-240
            Four1.5-3002.5-24010-30010-240
            Five1.5-3002.5-24010-30010-240
            3+14-3004-24016-30016-240
            3+24-3004-24016-30016-240
            4+14-3004-24016-30016-240

            The table shows included in the product standards, specifications and section, according to the requirements of users can also produce
            Five, the scope of production:

            Model

            Core number

            Rated voltage of kV

            3.6/6

            6/6, 6/10

            8.7/10, 8.7/15

            12/20

            21/35

            26/35

            The conductive wire core nominal section mm2

            YJV
            YJLV
            ZR-YJV
            ZR- YJLV

            One

            25-400

            25-400

            25-400

            35-400

            50-400

            50-400

            Three

            25-300

            25-300

            25-300

            35-300

            50-185

            50-185

            YJV22
            YJLV22
            ZR-YJV22
            ZR-YJLV

            Three

            25-300

            25-300

            25-300

            35-300

            50-185

            50-185

            YJV32
            YJLV32
            ZR-YJV32
            ZR-YJLV32

            One

            25-400

            25-400

            25-400

            35-400

            50-400

            50-400

            Three

            25-300

            25-300

            25-300

            35-300



            Not included in the list of product standards, specifications and section, according to the requirements of users can also produce.
            Sixth, conductor DC resistance:

            Nominal cross-section of conductor

            Conductor DC resistance
            Omega /km

            Mm2


            copper

            aluminum

            One point five

            Twelve point one

            -

            Two point five

            Seven point four one

            -

            Four

            Four point six one

            Seven point four one

            Six

            Three point zero eight

            Four point six one

            Ten

            One point eight three

            Three point zero eight

            Sixteen

            One point one five

            One point nine one

            Twenty-five

            Zero point seven two seven

            One point two zero

            Thirty-five

            Zero point five two four

            Zero point zero eight six eight

            Fifty

            Zero point three eight seven

            Zero point six four one

            Seventy

            Zero point two six eight

            Zero point four four three

            Ninety-five

            Zero point one nine three

            Zero point three two zero

            One hundred and twenty

            Zero point one five three

            Zero point two five three

            One hundred and fifty

            Zero point one two four

            Zero point two zero six

            One hundred and eighty-five

            Zero point zero nine nine one

            Zero point one six four

            Two hundred and forty

            Zero point zero seven five four

            Zero point one two five

            Three hundred

            Zero point zero six zero one

            Zero point one zero zero

            Four hundred

            Zero point zero four seven four

            Zero point zero seven seven eight

            Five hundred

            Zero point zero three six six

            Zero point zero six Zero Five

            3+2, 4+1, 3+1 cable, cable 3, 4 and 1 (the main core), 2 (auxiliary core) between equipment.

            The 120 main core
            (mm2)
            Two point fiveFourSixTenSixteenTwenty-fiveThirty-fiveFiftySeventyNinety-fiveOne hundred and twentyOne hundred and fiftyOne hundred and eighty-fiveTwo hundred and forty
            The auxiliary core
            (mm2)
            One point fiveTwo point fiveFourSixTenSixteenSixteenTwenty-fiveThirty-fiveFiftySeventySeventyNinety-fiveOne hundred and twenty

            Seven, the flow of cable section:

            conductorConductor sectionNon armoured cableArmoured cable
            Single core3 coreSingle core3 core
            atmospheresoilatmospheresoilatmospheresoilatmospheresoil
            Copper conductorOne point fiveThirtyForty-threeTwenty-oneTwenty-five----
            Two point fiveFortyFifty-sevenTwenty-eightThirty-three--Twenty-eightThirty-three
            FourFifty-threeSeventy-fourThirty-sevenForty-four--Thirty-sevenForty-three
            SixSixty-sevenNinety-fourForty-sixFifty-four--Forty-sevenFifty-four
            TenNinety-threeOne hundred and twenty-sevenSixty-threeSeventy-threeOne hundred and fiveOne hundred and twenty-fiveSixty-threeSeventy-one
            SixteenOne hundred and twenty-fourOne hundred and sixty-fiveEighty-fourNinety-fourOne hundred and thirty-sixOne hundred and sixty-twoEighty-fourNinety-two
            Twenty-fiveOne hundred and sixty-eightTwo hundred and thirteenOne hundred and nineOne hundred and twentyOne hundred and eightyTwo hundred and tenOne hundred and tenOne hundred and eighteen
            Thirty-fiveTwo hundred and sevenTwo hundred and fifty-sixOne hundred and thirty-twoOne hundred and forty-fourTwo hundred and twentyTwo hundred and fifty-threeOne hundred and thirty-fourOne hundred and forty-one
            FiftyTwo hundred and fifty-twoThree hundred and fourOne hundred and fifty-nineOne hundred and sixty-nineTwo hundred and sixty-fiveTwo hundred and ninety-nineOne hundred and sixty-oneOne hundred and sixty-seven
            SeventyThree hundred and eightThree hundred and seventy-twoOne hundred and ninety-fiveTwo hundred and fiveThree hundred and twenty-twoThree hundred and sixty-sixOne hundred and ninety-sevenTwo hundred and three
            Ninety-fiveThree hundred and eighty-fourFour hundred and forty-nineTwo hundred and thirty-sevenTwo hundred and forty-fiveThree hundred and ninety-eightFour hundred and forty-twoTwo hundred and thirty-nineTwo hundred and forty-two
            One hundred and twentyFour hundred and thirty-nineFive hundred and twelveTwo hundred and seventy-threeTwo hundred and seventy-eightFour hundred and sixty-fiveFive hundred and fiveTwo hundred and seventy-fiveTwo hundred and seventy-four
            One hundred and fiftyFive hundred and sevenFive hundred and seventy-fiveThree hundred and tenThree hundred and nineFive hundred and twenty-oneFive hundred and sixty-sevenThree hundred and fourteenThree hundred and five
            One hundred and eighty-fiveFive hundred and ninety-oneSix hundred and fiftyThree hundred and fifty-fiveThree hundred and forty-sevenSix hundred and fourSix hundred and thirty-nineThree hundred and fifty-fourThree hundred and forty-one
            Two hundred and fortySix hundred and ninety-fourSeven hundred and fifty-sevenFour hundred and sixteenThree hundred and ninety-nineSeven hundred and sixSeven hundred and forty-fourFour hundred and fourteenThree hundred and ninety-two
            Three hundredEight hundred and tenEight hundred and fifty-fiveFour hundred and seventy-threeFour hundred and forty-sixEight hundred and nineteenEight hundred and forty-two--
            Four hundredNine hundred and thirty-sevenNine hundred and seventy-six--Nine hundred and forty-nineNine hundred and sixty-two--
            Five hundredOne thousand and seventy-eightOne thousand one hundred and ten--One thousand and ninety-fourOne thousand and ninety-four--










            Aluminum conductorTenSeventy-oneNinety-sevenForty-eightFifty-sixEighty-oneNinety-sixForty-nineFifty-five
            SixteenOne hundred and twenty-oneOne hundred and sixty-twoEighty-twoNinety-twoOne hundred and thirty-threeOne hundred and fifty-nineEighty-twoNinety
            Twenty-fiveOne hundred and thirtyOne hundred and sixty-fiveEighty-fiveNinety-threeOne hundred and fortyOne hundred and sixty-threeEighty-fiveNinety-two
            Thirty-fiveOne hundred and sixtyOne hundred and ninety-nineOne hundred and twoOne hundred and elevenOne hundred and seventyOne hundred and ninety-sixOne hundred and fourOne hundred and ten
            FiftyOne hundred and ninety-fiveTwo hundred and thirty-fiveOne hundred and twenty-threeOne hundred and thirty-oneTwo hundred and fiveTwo hundred and seventy-twoOne hundred and twenty-fourOne hundred and twenty-nine
            SeventyTwo hundred and thirty-nineTwo hundred and eighty-nineOne hundred and fifty-twoOne hundred and fifty-nineTwo hundred and fiftyTwo hundred and eighty-fourOne hundred and fifty-threeOne hundred and fifty-eight
            Ninety-fiveTwo hundred and ninety-eightThree hundred and forty-eightOne hundred and eighty-fourOne hundred and ninetyTwo hundred and eightThree hundred and forty-threeOne hundred and eighty-fiveOne hundred and eighty-eight
            One hundred and twentyThree hundred and fortyThree hundred and ninety-eightTwo hundred and thirteenTwo hundred and sixteenThree hundred and sixty-oneThree hundred and ninety-twoTwo hundred and fourteenTwo hundred and thirteen
            One hundred and fiftyThree hundred and ninety-twoFour hundred and forty-fiveTwo hundred and forty-oneTwo hundred and fortyFour hundred and fourFour hundred and thirty-nineTwo hundred and forty-twoTwo hundred and thirty-seven
            One hundred and eighty-fiveFour hundred and fifty-nineFive hundred and fiveTwo hundred and seventy-sevenTwo hundred and seventy-oneFour hundred and sixty-nineFour hundred and ninety-sevenTwo hundred and seventy-sevenTwo hundred and sixty-seven
            Two hundred and fortyFive hundred and thirty-nineFive hundred and eighty-nineThree hundred and twenty-sixThree hundred and twelveFive hundred and forty-nineFive hundred and seventy-eightThree hundred and twenty-fiveThree hundred and eight
            Three hundredSix hundred and twenty-nineSix hundred and sixty-fourTwo hundred and seventy-twoThree hundred and fifty-oneSix hundred and thirty-sixSix hundred and fifty-four--
            Four hundredSeven hundred and thirty-oneSeven hundred and sixty-two--Seven hundred and forty-oneSeven hundred and fifty-one--
            Five hundredEight hundred and forty-fiveEight hundred and seventy--Eight hundred and fifty-eightEight hundred and fifty-eight--

            Eight, <strong> XLPE insulated power cable</strong> model:

            projectCodeExplain
            Flame retardant code/
            ZR
            Non flame retardant can be omitted
            Flame retardant
            Insulating materialsYJCrosslinked PVC material
            Jacket materialVpolyvinyl chloride
            Sheathing materialsTwenty-two
            Thirty-two
            Steel tape
            Steel wire armoured
            Heat resistant gradeOne
            Ninety
            One hundred and five
            The maximum operating temperature is 70 DEG C, can be omitted
            The maximum operating temperature is 90 DEG C
            The maximum operating temperature is 105 DEG C
            Rated voltage0.6/1KV
            26/35KV
            The rated working voltage of U0/U is 0.6/1KV
            The rated working voltage of U0/U is 26/35KV
            Specifications
            Fill in the core number * conductor cross-section (N * S)
            N:1 234 3+1 5 4+1 3+2
            S:1.5 2.54610...... 240mm2

            Nine, specifications said:
            1:0.6/1KV copper core XLPE insulated PVC sheathed 120mm2 3 core XLPE power cable said: YJV0.6/1KV 3 * 120mm
            2:8.7/10KV copper core XLPE insulated PVC sheathed steel tape armored core, 3 70mm2 high voltage XLPE power cable is YJV228.7/10KV 3 * 70.
            Ten, delivery length: cable should not less than 100 meters, 50 meters above the allowed short-term delivery, the number does not exceed 10% of the total length of delivery; if there are special requirements of both supply and demand can be negotiated.