1. <noframes id="S_RI8G">
      <noframes id="S_RI8G"><kbd></kbd>
          1. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
            0517-86918678
            Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
            Tel:0517-86918678
            Fax:0517-86918679
            Email:zhongweick@https://clubargos.com
            Post Encoding:211600

            Cables for nuclear power plants

            覈電(dian)站用電(dian)纜(lan).jpg
            • 覈(he)電(dian)站用(yong)電纜.jpg
            Cables for nuclear power plants are suitable for connecting instruments, computers and data processi…

            Description:

            A cable, an overview:
            Cable for nuclear power station Suitable for nuclear reactor safety inside and outside shell (K2) and nuclear reactor containment vessel (K3) and instrumentation, computer and data processing system. (executive standard: the product according to IEEE383 and RCC-E standard).
            Two, product use:
            Cable for nuclear power station Applicable to the nuclear power plant and the flame retardant has special requirements in place of rated voltage 0.6/1kV.
            Three, cable characteristics:
            Rated voltage Uo/U 0.6/1kV
            The conductor allowed working temperature of 90 DEG C, short circuit (duration = 5S) the temperature of 50 DEG C
            Cable laying temperature not lower than 0 DEG C, laying temperature lower than 0 DEG C, should be heated
            The minimum bending radius: not less than 8 times the diameter of the cable shield cable, shielding type not less than 6 times of cable diameter
            Allow the lowest temperature environment for running cable: -40 C
            Four, the special performance of cable:
            The cable can withstand GB/T12666.5 (IEC332-1) standard bundle burning experiment
            Insulation wire can withstand GB/T12666.2 cable (IEC332-1) vertical burning test standard
            The performance of low smoke cable with GB/17651.7 (IEC6075-2) standard, the transmittance is greater than or equal to 60
            The performance of low halogen (IEC60754-2) cable complies with the GB/T17650.2 standard, pH = 4.3, the conductivity of <10us/mm
            Five, Cable for nuclear power station Electrical performance:

            Cable conductor20 degrees of conductor resistanceinsulation resistance
            Sectional areastructureUntinnedTinC = 20C = 60C = 90
            Zero point three five7/0.25Fifty-seven point sixSixty point threeOne thousand five hundred and twenty-twoFifteen point twoOne point five two
            Zero point five7/0.30Thirty-sixThirty-six point sevenOne thousand three hundred and fiftyThirteen point fiveOne point three five
            Zero point seven five7/0.37Twenty-four point fiveTwenty-four point sevenOne thousand one hundred and sixty-eightEleven point sevenOne point one seven
            One7/0.43Eighteen point oneEighteen point twoOne thousand one hundred and seventy-oneEleven point sevenOne point one seven
            One point five7/0.52Twelve point oneTwelve point twoOne thousand and twentyTen point twoOne point zero two
            Two point five7/0.68Seven point four oneSeven point five sixEight hundred and thirty-twoEight point three twoZero point eight three
            Four7/0.85Four point six nineFour point seven zeroSix hundred and ninety-sevenSix point nine sevenZero point six nine seven

            Six, <strong> nuclear power cable</strong> model:

            ModelProduct name
            HKYJE-K3Nuclear power plant with 1E class K3 XLPE insulation polyolefin sheath hydrogen low smoke halogen free flame-retardant control cable
            HKYJEP-K3Use the 1E class K3 XLPE insulation polyolefin sheathed copper wire woven shield hydrogen low smoke halogen free flame-retardant control cable for nuclear power station
            HKYJEP2-K3Use the 1E class K3 XLPE insulation polyolefin hydrogen sheathed composite copper plastic tape wrapped shield low smoke halogen-free flame retardant control cable for nuclear power station
            HKYJE24-K3Nuclear power plant with 1E class K3 XLPE insulation polyolefin hydrogen sheathed control cable low smoke halogen-free flame retardant
            HKYJEP-24-K3Use the 1E class K3 XLPE insulation polyolefin hydrogen sheathed copper wire woven shield steel tape armored low smoke halogen-free flame retardant control cable for nuclear power plant
            HKYJEP2-24-K3Use the 1E class K3 XLPE insulation polyolefin hydrogen sheathed composite copper plastic tape wrapped shield steel tape armored low smoke halogen-free flame retardant control cable for nuclear power plant
            HKYJGE-K3Nuclear power plant with 1E class K3 XLPE insulated flame-retardant control cable of oxygen separating layer of polyolefin sheath low smoke halogen hydrogen
            HKYJGEP-K3Nuclear power plant with 1E class K3 XLPE insulated hydrogen oxygen insulation layer polyolefin sheathed copper wire woven shield low smoke halogen-free flame retardant control cable
            HKYJGEP2-K3Nuclear power plant with 1E class K3 XLPE insulation polyolefin hydrogen oxygen insulation layer sheathed composite copper plastic tape wrapped shield low smoke halogen-free flame retardant control cable
            HKYJGE24-K3Nuclear power plant with 1E class K3 XLPE insulated control cable oxygen barrier flame retardant polyolefin hydrogen sheathed steel tape armored low smoke halogen-free
            HKYJGEP-24-K3Nuclear power plant with 1E class K3 XLPE insulated hydrogen oxygen insulation layer polyolefin sheathed copper wire woven shield steel tape armored low smoke halogen-free flame retardant control cable
            HKYJGEP2-24-K3Nuclear power plant with 1E class K3 XLPE insulated hydrogen oxygen insulation layer polyolefin sheathed composite copper plastic wrap to shield steel tape armored low smoke halogen-free flame retardant control cable
            HKXE-K3Nuclear power plant with 1E class K3 ethylene propylene rubber insulated low smoke halogen-free flame retardant polyolefin sheathed control cable
            HKXEP-K31E class K3 ethylene propylene rubber insulated polyolefin sheathed copper braid shielding low smoke halogen-free flame retardant control cable for nuclear power station
            HKXEP2-K31E class K3 ethylene propylene rubber insulated copper plastic wrapped shielding low smoke halogen-free flame retardant control cable composite with nuclear power plant
            HKXE24-K3Nuclear power plant with 1E class K3 ethylene propylene rubber insulated polyolefin sheathed steel tape armored low smoke halogen-free flame retardant control cable
            HKXEP-24-K31E class K3 ethylene propylene rubber insulated copper wire braid shield steel tape armored low smoke halogen-free flame retardant control cable for nuclear power plant
            HKXEP2-24-K31E class K3 ethylene propylene rubber insulated copper plastic wrapped shield steel tape armored low smoke halogen-free flame retardant control cable composite with nuclear power plant
            HKXGE-K3Nuclear power plant with 1E class K3 ethylene propylene rubber insulating oxide layer polyolefin sheath low smoke halogen-free flame retardant control cable
            HKXGEP-K31E class K3 ethylene propylene rubber insulated polyolefin sheathed copper braid shielding low smoke halogen-free flame retardant control cable for nuclear power station
            HKXGEP2-K31E class K3 ethylene propylene rubber insulating oxide layer polyolefin sheathed copper plastic wrapped shielding low smoke halogen-free flame retardant control cable composite with nuclear power plant
            HKXGE24-K3Nuclear power plant with 1E class K3 ethylene propylene rubber insulating oxide layer polyolefin sheathed steel tape armored low smoke halogen-free flame retardant control cable
            HKXGEP-24-K3Nuclear power plant with 1E class K3 ethylene propylene rubber insulating oxide layer polyolefin sheathed copper wire woven shield steel tape armored low smoke halogen-free flame retardant control cable
            HKXGEP2-24-K31E class K3 ethylene propylene rubber insulating oxide layer a polyolefin sheathed copper plastic wrapped shield steel tape armored low smoke halogen-free flame retardant control cable composite with nuclear power plant

            Seven, code name and meaning:

            projectCodeCode meaning
            Series codeHKControl cable for nuclear power station
            Insulating materialsYJCrosslinked polyethylene
            XEthylene propylene rubber
            Oxygen barrier layerGInorganic flame retardant
            Jacket materialEThermoplastic polyolefin
            Shielding materialPCopper or tinned copper braid
            P2Copper plastic composite belt winding
            Sheathing materialsTwenty-fourSteel tape armoured polyolefin sheath
            The quality of the firm levelK31E class K3
            SpecificationsCore number * nominal cross section2-37 core 0.35-4mm2


            Browse:
            Return To The Top

            分(fen)亯(xiang)到(dao):

            hKwNA

              1. <noframes id="S_RI8G">
                <noframes id="S_RI8G"><kbd></kbd>